期刊文献+

考虑土壤频变特性的接地系统有限元模型 被引量:7

The FEM Model of Grounding System Considering Soil Frequency-Dependence
原文传递
导出
摘要 基于电磁场理论的有限元法(FEM)和傅里叶变换相结合,通过引入Visacro-Alipio土壤频变公式,建立了可以考虑土壤电参数频变性的接地系统有限元模型。按照文献所给典型Heidler首次回击、后续回击雷电流冲击10 m水平接地极的试验条件,用Comsol Multiphysics软件的AC/DC模块建模仿真,将结果与文献试验数据对比,验证了模型的准确性。并进一步对3m垂直接地极分别埋于电导率0.01 S/m、0.002 S/m、0.001 S/m、0.0005 S/m土壤中时土壤频变性情况进行仿真分析,仿真发现,土壤频变性与土壤工频电阻率关系密切,土壤工频电阻率越高,频变作用越明显。在高电阻率(≥500Ω·m)土壤接地冲击计算中,有必要将土壤电参数的频变性考虑进来。 Based on the combination of the electromagnetic field theory FEM and Fourier transform, through introducing the Visacro-Alipio soil frequency-dependence expressions, a grounding FEM model which considered the soil frequency-dependence is established. According to the test condition in literature, the typical Heidler first and subsequent return stroke lightning current of a 10 m horizontal grounding electrode, based on the AC/DC module in Comsol Multiphysics software, the model is built, simulated, and the its accuracy is verified. Further simulation analysis of a 3 m vertical grounding electrode buried in 0.01 S/m, 0.002 S/m, 0.001 S/m, 0.0005 S/m soils is done to evaluate the frequency- dependence effect of soil electrical parameters, the results show that there is a close relationship between the soil frequency-dependence and soil power frequency resistivity: with the increase of soil power frequency resistivity, the frequency-dependence effect is more obvious. In the practical impulse calculation of high resistivity (≥ 500μm) soil, it is necessary to take the frequency-dependence of soil electrical parameters into account.
出处 《电瓷避雷器》 CAS 北大核心 2015年第5期100-105,110,共7页 Insulators and Surge Arresters
基金 国家自然科学基金(编号:51307152)
关键词 频变性 有限元 接地 Heidler雷电流 傅里叶变换 Comsol MULTIPHYSICS frequency-dependence FEM grounding Heidler lightning curren Fourier transform Comsol Muhiphysics
  • 相关文献

参考文献17

  • 1SILVERIO Visacr~ A comprehensive approach to the ground- ing response to lightning currents[J]. IEEE Transactions on Power Delivery, 2007,22 ( 1 ):381-386.
  • 2司马文霞,李晓丽,袁涛.考虑土壤非线性特性的接地网冲击特性分析方法[J].中国电机工程学报,2009,29(16):127-132. 被引量:46
  • 3何金良,孔维政,张波.考虑火花放电的杆塔冲击接地特性计算方法[J].高电压技术,2010,36(9):2107-2111. 被引量:29
  • 4Portela, C., Frequency and Transient Behavior of Grounding Systems -! Physical and Methodological Aspects, Proceeding of 1997 International Symposium on Electromagnetic Compatibility, pp:380 -384, August 1997, United States.
  • 5Portela C. Frequency and Transient Behavior of Grounding Systems-II Practical Application Examples, Proceeding of 1997 International Symposium on Electromagnetic Compatibility, pp:385-390, August 1997, United States.
  • 6VISACRO S,ALIPIO R. The Response of Grounding Elec- trodes to Lightning Currents: The Effect of Frequency-De- pendent Soil Resistivity and Permittivity[J]. IEEE Transac- tions on Electromagnetic Compatibility,2011,53(2).401-406.
  • 7VISACRO S, ALIPIO R. Frequency Dependence of Soil Parameters: Experimental Results, Predicting Formula and Influence on the Lightning Response of Grounding Elec- trodes [J]. IEEE Transactions on Power Delivery, 2012,27 (2):927-934.
  • 8邓长征,杨迎建,童雪芳,董晓辉,彭庆华.接地装置冲击特性研究分析[J].高电压技术,2012,38(9):2447-2454. 被引量:47
  • 9陈家宏,童雪芳,谷山强,李晓岚.雷电定位系统测量的雷电流幅值分布特征[J].高电压技术,2008,34(9):1893-1897. 被引量:153
  • 10Habjanic A,Trlep M. The simulation of the soil ionization phenomenon around the grounding system by the finite element method [J]. IEEE Transactions on Magnetic,2006, 42 (4) :867-870.