期刊文献+

双源CT低碘浓度对比剂联合低kV和非迭代重建技术在冠状动脉CTA检查中的临床价值 被引量:13

Clinical application of double source computed tomography with low-voltage and low-iodine concentration contrast agent using non-iterative reconstruction in coronary artery CT angiography
下载PDF
导出
摘要 目的:评价在不同碘浓度对比剂和不同管电压的条件下采用非迭代重建技术后冠状动脉CTA的图像质量,并探讨其临床价值。方法:选取解放军第九七医院2014年5-10月50例临床怀疑冠心病的患者,随机分为A、B两组,每组25例,A组检查条件为管电压120kVp、对比剂碘浓度370mg I/mL;B组为管电压100kVp、对比剂碘浓度270mg I/mL。对2组患者行冠状动脉CTA检查后,图像采用滤过反投影(FBP)法进行重建,分别测量及计算右冠状动脉(RCA)近段及左冠状动脉主干(LMA)的CT值、信噪比(SNR)、对比信噪比(CNR)、图像质量主观评分、CT容积剂量指数(CTDIvol)、剂量长度乘积(DLP)及有效辐射剂量(ED)。结果:2组间RCA近段、LMA管腔内CT值、SNR、CNR及图像质量主观评分的差异均无统计学意义(P>0.05),而2组间CTDIvol、DLP及ED比较B组均低于A组,有统计学意义(P<0.05)。结论:低碘浓度对比剂(270mg I/mL)联合低kV(100kVp)通过非迭代重建技术仍可获得管电压120kVp及对比剂碘浓度370mg I/mL扫描条件下相同质量的图像,不仅可以满足诊断需要,还可以减低辐射剂量。 Objective:To evaluate the image quality of different tube voltage with different iodine concentration contrast agent in coronary artery computed tomography angiography(CTA),and discuss its clinical value.Methods:Fifty patients underwent coronary artery CTA,and they were randomly assigned to 2groups,Group A(n=25)was scanned using120 kVp and 370 mg I/mL iodine concentration contrast agent,Group B(n=25)was scanned using 100 kVp and 270 mg I/mL iodine concentration contrast agent,images were reconstructed using filtered back projection(FBP).Then CT attenuation of two main branches(proximal RCA and LMA)of coronary artery,SNR,CNR,subjective scoring of image quality,volume CT dose idex(CTDIvol),dose length product(DLP)and effective dose(ED)were measured and compared.Results:The coronary artery CT attenuation,SNR,CNR and subjective scoring of the two groups had no statistically significant differences(Pvalue〉0.05),but the CTDIvol,DLP and ED of the two groups were statistically different(Pvalue〈0.05),and the data of Group B were all lower than those of Group A.Conclusion:The coronary artery CTA using 100 kVp with 270 mg I/mL iodinated contrast agent can provide similar image quality as compared with CTA using 120 kVp and 370 mg I/mL with non-iterative reconstruction,thus enabling to reduce radiation dose without loss of diagnostic information.
出处 《放射学实践》 北大核心 2015年第10期997-1000,共4页 Radiologic Practice
关键词 冠状动脉疾病 血管造影术 辐射剂量 Coronary artery disease Angiography Radiation dosage
  • 相关文献

参考文献4

二级参考文献23

  • 1Szucs-Farkas Z,Schilber F,Cullmann J,et al. Diagnostic accuracyof pulmonary CT angiography at low tube voltage : intraindividualcomparison of a normal-dose protocol at 120 kVp and a low-doseprotocol at 80 kVp using reduced amount of contrast medium in asimulation study. AJR Am J Roentgenol,2011,197 : W852-W859.
  • 2Utsunomiya D,Oda S,Funama Y,et al. Comparison of standard-and low-tube voltage MDCT angiography in patients withperipheral arterial disease. Eur Radiol,2010,20 : 2758-2765.
  • 3Oda S, Utsunomiya D, Funama Y, et al. A low tube voltagetechnique reduces the radiation dose at retrospective ECG-gatedcardiac computed tomography for anatomical and functionalanalyses. Acad Radiol ,2011,18 ; 991-999.
  • 4LaBounty TM,Leipsic J,Poulter R,et al. Coronary CT angiographyof patients with a normal body mass index using 80 kYp versus100 kVp: a prospective, multicenter, multivendor randomizedtrial. AJR Am J Roentgenol,2011,197 : W860-W867.
  • 5Wang D,Hu XH,Zhang SZ,et al. Image quality and doseperformance of 80 kV low dose scan protocol in high-pitch spiralcoronary CT angiography : feasibility study. Int J CardiovascImaging,2012 ,28 : 415423.
  • 6McCollough C,Cody D,Edyvean S,et al. The measurement,reporting,and management of radiation dose in CT. College Park:Tech Rep 96 Am Assoc Phy Med,2008 :1.
  • 7Weustink AC, Neefjes LA, Kyrzopoulos S, et al. Impact of heartrate frequency and variability on radiation exposure, image quality,and diagnostic performance in dual-source spiral CT coronaryangiography. Radiology,2009 ,253 :672-680.
  • 8Schueller-Weidekamm C,Schaefer-Prokop CM, Weber M,et al. CTangiography of pulmonary arteries to detect pulmonary embolism :improvement of vascular enhancement with low kilovoltagesettings. Radiology,2006,241:899-907.
  • 9Schindera ST,Nelson RC, Mukundan S Jr, et al. Hypervascular livertumors: low tube voltage,high tube current multi-detector row CT forenhanced detection-phantom study. Radiology ,2008,246 : 125-132.
  • 10W.P. Shuman,K.R. Branch,J.M. May,L.M. Mitsumori,D.W. Lockhart,T.J.Dubinsky,邱建星(译),唐光健(校).前瞻性和回顾性心电门控冠状动脉64层CT成像:影像质量和病人放射剂量的对照性研究[J].国际医学放射学杂志,2008,31(5):400-400. 被引量:129

共引文献137

同被引文献88

  • 1张兆琪,徐磊.同心协力,影像未来:心血管影像的发展与展望.中华放射学杂志,2013,47(1):24-26.
  • 2Dewey M,Zimmermann E,Deissenrieder F,et al.Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy:comparison of results with cardiac catheterization in a head-tohead pilot investigation.Circulation,2009,120(10):867-875.
  • 3Leber AW,Johnson T,Becker A,et al.Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease.Eur Heart J,2007,28(19):2354-2360.
  • 4Fleischmann D.Use of high concentration contrast media:principles and rationale-vascular district.Eur J Radiol,2003,45(Suppl 1):S88-S93.
  • 5Cademartiri F,De Monye C,Pugliese F,et al.High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography:iopromide 370versus coronary angiography:iopromide 370 versus iomeprol400.Invest Radiol,2006,41(3):349-353.
  • 6Setty BN,Sahani DV,Ouellette-Piazzo K,et al.Comparison of enhancement,image quality,cost,and adverse reactions using 2different contrast medium concentrations for routine chest CT on16-slice MDCT.J Comput Assist Tomogr,2006,30(5):818-822.
  • 7Awai K,Inoue M,Yagyu Y,et al.Moderate versus high concentration of contrast material for aortic and hepatic enhancement and tumor to liver contrast at multidetector row CT.Radiology,2004,233(3):682-688.
  • 8Liss P,Persson PB,Hansell P,et al.Renal failure in 57 925patients undergoing coronary procedures using iso-osmolar or low-osmolar contrast media.Kidney Int,2006,70(10):1811-1817.
  • 9Seeliger E,Flemming B,Wronski T,et al.Viscosity of contrast media perturbs renal hemodynamics.J Am Soc Nephrol,2007,18(11):2912-2920.
  • 10Fei X,Du X,Yang Q,et al.64-MDCT coronary angiography:phantom study of effects of vascular attenuation on detection of coronary stenosis.Am J Roentgenol,2008,191(1):43-49.