针对30000 m3/h空分设备氧气产量偏低现象,详细分析故障原因,介绍了相应的处理措施、效果以及从中得到的经验教训。
Based on phenomena of oxygen yield not meeting normal value in a 30000m3/ h air separation unit,the cause of fault is analyzed in details. The treatment measures and their effects,as well as experiences and lessons from the fault,are presented.
出处
《山东化工》
CAS
2015年第19期93-93,98,共2页
Shandong Chemical Industry
关键词
空分设备
氧气产量
换热器
热端温差
air separation unit
oxygen yield
warm end temperature difference