摘要
A sensitive,stability-indicating gradient reverse phase ultra performance liquid chromatographic method has been developed for the quantitative estimation of nebivolol impurities in active pharmaceutical ingredient(API)and pharmaceutical formulation.Efficient chromatographic separation was achieved on an Acquity BEH C18 column(100 mm×2.1 mm,1.7μm)with mobile phase of a gradient mixture.The flow rate of the mobile phase was 0.18 mL/min with column temperature of 30℃and detection wavelength of 281 nm.The relative response factor values of(R*)-2-(benzylamino)-1-((S*)-6-fluorochroman-2-yl)ethanol((R*S*)NBV-1),(R)-1-((R)-6-fluorochroman-2-yl)-2-((S)-2-((S)-6-fluoro-chroman-2-yl)-2-hydroxyethylamino)ethanol((RRSS)NBV-3),1-(chroman-2-yl)-2-(2-(6-fluorochroman-2-yl)-2-hydroxy ethyl amino)ethanol(monodesfluoro impurity),(S)-1-((R)-6-fluorochroman-2-yl)-2-((R)-2((S)-6-fluoro-chroman-2-yl)-2-hydroxyethylamino)ethanol hydrochloride((RSRS)NBV-3)and(R*)-1-((S*)-6-fluorochroman-2-yl)-2-((S*)-2-((S*)-6-fluoro-chroman-2-yl)-2-hydroxyethylamino)ethanol((R*S*S*S*)NBV-2)were 0.65,0.91,0.68,0.92 and 0.91 respectively.Nebivolol formulation sample was subjected to the stress conditions of acid,base,oxidative,hydrolytic,thermal,humidity and photolytic degradation.Nebivolol was found to degrade significantly under peroxide stress condition.The degradation products were well resolved from nebivolol and its impurities.The peak purity test results confirmed that the nebivolol peak was homogenous and pure in all stress samples and the mass balance was found to be more than 98%,thus proving the stability-indicating power of the method.The developed method was validated according to International Conference on Hormonization(ICH)guidelines with respect to specificity,linearity,limits of detection and quantification,accuracy,precision and robustness.
A sensitive,stability-indicating gradient reverse phase ultra performance liquid chromatographic method has been developed for the quantitative estimation of nebivolol impurities in active pharmaceutical ingredient(API)and pharmaceutical formulation. Efficient chromatographic separation was achieved on an Acquity BEH C18 column(100 mm×2. 1 mm,1. 7 μm)with mobile phase of a gradient mixture. The flow rate of the mobile phase was 0. 18 mL / min with column temperature of 30 ℃ and detection wavelength of 281 nm.The relative response factor values of(R*)-2-(benzylamino)-1-((S*)-6-fluorochroman-2-yl)ethanol((R*S*)NBV-1),(R)-1-((R)-6-fluorochroman-2-yl)-2-((S)-2-((S)-6-fluoro-chroman-2-yl)-2-hydroxyethylamino)ethanol((RRSS)NBV-3),1-(chroman-2-yl)-2-(2-(6-fluorochroman-2-yl)-2-hydroxy ethyl amino)ethanol(monodesfluoro impurity),(S)-1-((R)-6-fluorochroman-2-yl)-2-((R)-2((S)-6-fluoro-chroman-2-yl)-2-hydroxyethylamino)ethanol hydrochloride((RSRS) NBV-3) and(R*)-1-((S*)-6-fluorochroman-2-yl)-2-((S*)-2-((S*)-6-fluoro-chroman-2-yl)-2-hydroxyethylamino)ethanol((R*S*S*S*)NBV-2)were 0. 65,0. 91,0. 68,0. 92 and 0. 91 respectively. Nebivolol formulation sample was subjected to the stress conditions of acid,base,oxidative,hydrolytic,thermal,humidity and photolytic degradation. Nebivolol was found to degrade significantly under peroxide stress condition. The degradation products were well resolved from nebivolol and its impurities. The peak purity test results confirmed that the nebivolol peak was homogenous and pure in all stress samples and the mass balance was found to be more than 98%,thus proving the stability-indicating power of the method. The developed method was validated according to International Conference on Hormonization(ICH)guidelines with respect to specificity,linearity,limits of detection and quantification,accuracy,precision and robustness.
出处
《色谱》
CAS
CSCD
北大核心
2015年第10期1051-1058,共8页
Chinese Journal of Chromatography
关键词
高效液相色谱
高分辨质谱
稻曲病菌毒素
水稻
reverse phase ultra performance liquid chromatography
stability-indicating
nebivolol
impurities
International Conference on Hormonization(ICH)guidelines