期刊文献+

前路经寰枕寰枢关节锁定钛板螺钉内固定系统的匹配性研究 被引量:3

Compatible study of anterior occiput to axis transarticular locking plate system
下载PDF
导出
摘要 目的观察新型前路经枕寰枢关节锁定钛板螺钉内固定系统与枕颈复合体的匹配性,探讨此内固定系统临床应用的可行性。方法对枕颈部CT扫描数据进行三维重建,并通过数字化模拟手术进行解剖学匹配实验。通过观察钛板枢椎椎体前表面的切合性及螺钉的走行,测量经关节螺钉的理想钉道参数,评估此内固定系统与枕颈复合体的匹配性。结果钛板与枢椎椎体前表面相匹配;经关节螺钉均穿过寰枕关节及寰枢关节进入枕骨髁,无穿出骨质者,螺钉均未损伤舌下神经管。椎体固定螺钉均位于枢椎椎体骨质内,未进入椎管及椎间隙。经关节螺钉钉道理想钉道参数与内固定系统实际钉道参数差异无统计学意义。结论前路经寰枕寰枢关节锁定钛板螺钉内固定系统与枕颈复合体解剖学匹配性较好,具有临床应用可行性。 Objective To investigate the feasibility of anterior occiput to axis transarticular locking plate system through analyzing its compatibility with the occipital cervical complex. Methods Thirty health cases were selected from the date of head-neck CT examination randomly. 3D models of occipital cervical complex were reconstructed on the date. The anatomical compatibility was assessed between the systems and the 30 cases through surgical simulation by computer via digital technology. The morphological compatibility between the titanium plate and the surface of the axis as well as the screw trajectory were observed. The ideal screw trajectory parameters of trans- articular screws were measured so that the compatibility could be assessed. Results There was a morphological match between the titanium plate and the surface of the axis. All the trans-articular screws passed through the atlanto-occipital articulation and the atlanto-axial articulation, without piercing the bones or going into the hypoglossal canal. The fixed screws were in the axial vertebral body without going into the intervertebral space and the spinal canal. There was no significant difference between the ideal screw trajectory and the actual screw trajectory. Conclusions Anterior occiput to axis transarticular locking plate system has a better anatomic compatibility with the Chinese occipital cervical complex. And it is feasible in clinical application.
出处 《中国临床解剖学杂志》 CSCD 北大核心 2015年第5期531-534,共4页 Chinese Journal of Clinical Anatomy
基金 全军医学科学研究"十一五"计划攻关课题(08G031)
关键词 前路 寰枕关节 寰枢关节 枕颈融合 经关节螺钉 匹配 Anterior Atlantooccipital joint Atlantoaxial joint Occipitocervical fusion Transarticular screw Compatibility
  • 相关文献

参考文献10

  • 1Dvorak MF, Fisher C, Boyd M. Anterior occiput-to-axis screw fixation: part I: a case report, description of a new technique, and anatomical feasibility analysis [J] . Spine, 2003, 28(3): E54-60,.
  • 2Dvorak MF, Sekeramayi F, Zhu Q. Anterior occiput to axis screw fixation: part II: a biomechanical comparison with posterior fixation techniques [J]. Spine, 2003, 28(3): 239-245.
  • 3Cai XH, Yu Y, Liu ZC. Three-dimensional finite element analysis of occipitocervical fixation using an anterior occiput-to-axis locking plate system: a pilot study [J]. Spine, 2014, 14(8): 1399-1409.
  • 4余洋,蔡贤华,黄卫兵,张美超,刘志超.前路经枕-寰-枢关节螺钉内固定力学的三维有限元分析[J].中国矫形外科杂志,2010,18(21):1804-1808. 被引量:5
  • 5蔡贤华,李明,黄卫兵,曾晓华,谭惠斌,郑宇,张中,李世梁.前路经枕寰枢关节螺钉内固定术的可行性及安全性研究[J].中华创伤骨科杂志,2012,14(3):188-192. 被引量:3
  • 6李明,蔡贤华,黄卫兵,张中,李世梁.前路经枕寰枢关节螺钉内固定的临床解剖学研究[J].中国矫形外科杂志,2011,19(23):1995-1999. 被引量:2
  • 7Kleweno CP, Zampini JM, White AP. Survival after concurrent traumatic dislocation of the atlanto-occipital and atlanto-axial joints: a case report and review of the literature[J]. Spine,2008,33(18):E659-662.
  • 8Sapkas G, Papadakis SA, Segkos D, et a1. Posterior instrumentation for occipitocervical fusion[J]. Open Orthop J, 2011, 5(6): 209-218.
  • 9Shen F, Chen B, Guo Q. Augmented reality patient-specific reconstruction plate design for pelvic and acetabular fracture surgery [J] . Int J Comput Assist Radiol Surg,2013, 8(2): 169-179.
  • 10Dérand P, R?nnar LE, Hirsch JM. Imaging, virtual planning, design, and production of patient-specific implants and clinical validation in craniomaxillofacial surgery [J]. Craniomaxillofac Trauma Reconstr,2012, 5(3): 137-144.

二级参考文献45

  • 1郭翔,倪斌.颈椎生物力学模型的应力及进展[J].中国矫形外科杂志,2006,14(16):1225-1227. 被引量:6
  • 2章文杰,倪斌,王健,蒋涛,陶春生,任中武,王明飞,郭翔.前路经寰枢关节螺钉内固定行枕颈融合的解剖学研究[J].中国脊柱脊髓杂志,2006,16(9):681-684. 被引量:7
  • 3Panjabi MM ,Dvorak J, Duranceau J ,et al. Three- dimensional movements of the upper cervical spine[ J ]. Spine, 1988,7:728 -720.
  • 4Uribe JS, Ramos E, Youssef AS, et al. Craniocervical fixation with occipital condyle screws: biomechanical analysis of a novel technique [J]. Spine,2010,9:931 -938.
  • 5Richter M, Cakir B, Schmidt R. Cervical pedicle screws : conventional versus computer- assisted placement of cannulated screws[ J]. Spine, 2005,30:2280 - 2287.
  • 6Papadopoulos EC, Girardi FP, Sama A, et al. Accuracy of single - time, multilevel registration in imageguided spinal surgery [J]. Spine,2005,3:263 - 267.
  • 7Easley SK, Pal S, Tomaszewski PR, et al. Finite clement - based probabilistic analysis tool for orthopaedic applications[J]. Comput Methods Programs Biomed,2007,1 : 32 - 40.
  • 8Panjabi MM. Cervical spine models for biomechanical research [J]. Spine, 1998,24 : 2684 - 2700.
  • 9Gonzalez LF, Crawford NR, Chamberlain RH, et al. Craniovertebral junction fixation with transarticular screws: biomcchanical analysis of a novel technique[J]. J Neurosurg ,2003, 1:202 - 209.
  • 10Finn MA, Bishpo FS, Dailey AT. Surgical treatment of occipitocervical instability [ J ]. Neurosurgery ,2008,5:961 - 969.

共引文献6