期刊文献+

烧结烟气SO2监测干扰因素分析及改进 被引量:4

Analysis of Disturbance Factor of Sinter Flue Gas Sulfur Dioxide Monitoring and Improvement
下载PDF
导出
摘要 某钢铁集团公司在实施烧结脱硫工程后,脱硫出口烟气连续监测数据与日常手工比对监测数据相比超过国家规定。为此通过定电位电解法、非分散红外吸收法和紫外差分吸收光谱法同时进行了比对监测,人为调整了运行工况,并使用一氧化碳气体标定监测设备分析了干扰因素,提出了改进建议。 After implemented sinter desulfurization in an iron and steel group shows that the constant flue gas monitoring data of the desulfurization outlet violate nati compared with daily manual monitoring data. For this, tential electrolysis method, non-dispersive infrared tion spectroscopy together corporation, it onal regulation compare the monitoring data by using fixed poabsorption method, and differential optical absorp- Adjust the running condition. And analyze the disturbance factor via carbon monoxide gas calibration equipment. Propose improving suggestion.
出处 《冶金设备管理与维修》 2015年第5期16-18,21,共4页 Metallurgical Equipment Management and Maintenance
关键词 二氧化硫 比对监测 干扰因素 Sulfur dioxide, comparison monitoring, disturbance factor
  • 相关文献

同被引文献25

引证文献4

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部