实验对C-MBR在好氧环境和厌氧/好氧交替环境下的膜污染进行了研究。实验结果表明CMBR在厌氧/好氧交替环境下运行时,反应器内EPS、SMP和MLVSS均比好氧环境运行下低。C-MBR在厌氧/好氧交替环境下运行不仅可以明显缓解膜污染,而且曝气量减少可以降低处理单位污水的能耗。
The effects of the C- MBR in the aerobic environment and alternating anaerobic / aerobic environment on membrane fouling are studied in the experiment. Results show that,the EPS,SMP and MLVSS of the C- MBR in the alternating anaerobic / aerobic environment are all lower than that in the aerobic environment. The C- MBR that runs in alternating anaerobic / aerobic environment can not only alleviate the membrane fouling obviously,but also reduce energy consumption per unit volume of sewage treatment by reducing the aeration.
出处
《工业安全与环保》
北大核心
2015年第10期4-6,共3页
Industrial Safety and Environmental Protection
基金
国家自然科学基金(51108108)
广西自然科学基金(2013GXNSFCA019018)
广西科学研究与技术开发(桂科合1298014-14
桂科合1347004-15)
广西高校科学技术研究项目(2013ZD031
2013ZL076)