期刊文献+

湖南省火电机组脱硫及脱硝自动投运情况调查及分析

Investigation and Analysis of FGD and Denitration Auto-Control System for Main Thermal Power Units in Hunan Province
下载PDF
导出
摘要 文章对湖南省主要火电机组脱硫及脱硝自动控制系统的投运情况进行了全面调查,对其中最重要的脱硫吸收塔浆液pH值和脱硝氨气流量两个自动控制系统的控制策略进行了分析,指出了多数机组脱硫及脱硝自动控制系统中存在自动投运情况不佳、部分测点准确度较低、设备状况不理想、有设计缺陷等主要问题,并提出了有针对性的建议。 An investigation of FGD and denitration auto-control system for the main thermal power units in Hunan Province has been carried out in this paper, the control strategy of slurry pH control system of absorption tower and denitration ammonia flow control system has been analyzed. It has discovered that the problems existing in many units such as: the bad auto-control situation, the low control accuracy, the bad equipment condition, and some design defects. For these problems, some pertinent recommendations are proposed in this paper.
出处 《自动化博览》 2015年第10期86-89,共4页 Automation Panorama1
关键词 湿法脱硫 脱硝 自动控制系统 PH值 氨气流量 Wet desulfurization Denitration Auto-control system pH Ammonia flow
  • 相关文献

参考文献7

  • 1GB13223-2011.火电厂大气污染物排放标准[S].环境保护部:国家质量监督检验检疫总局,2011.
  • 2崔希,吴莉娟,黄达等.基于先进控制技术的660MW超超临界机组SCR脱硝控制方案[c].2013年全国发电厂热工自动化专业年会论文集.
  • 3陈耀龙.脱硫系统吸收塔浆液PH值控制与仿真[J].应用能源技术,2011(11):21-25. 被引量:3
  • 4景建平,吴文辉.石灰-石膏湿法脱硫工艺主要运行参数控制调整探析[J].热力发电,2011,40(11):14-16. 被引量:10
  • 5朱晓星,盛锴,王伯春等.湖南省火电机组脱硫脱硝自动投运情况分析及优化总结报告[R].国网湖南省电力公司电力科学研究院,2014.
  • 6阎维平,刘忠,王春波等.电站燃煤锅炉石灰石湿法延期脱硫装置运行与控制[M].北京:中国电力出版社,2006.
  • 7盛锴,王伯春,寻新等.基于系统建模的SCR脱硝喷氯自动系统优化[c].湖南省电机工程学会热工自动化专委会2014年学术会议论文集,2014.

二级参考文献9