PDCA循环在根管充填质量管理中的应用 被引量:4

Application of PDCA in the Quality Control of Root Canal Obturation
下载PDF
导出
摘要 目的:探讨PDCA循环在根管充填质量管理中的应用效果。方法:将PDCA循环应用于根管充填的管理过程中,比较实施前后根管充填的恰填率。结果:根管治疗的总恰填率达到PDCA的预定目标。磨牙根管的恰填率由实施前85.84%提高到90.45%,差异具有统计学意义。结论:PDCA循环提高了磨牙根管充填质量,在根管充填质量管理中发挥积极作用。 Objective:To evaluate the effect of PDCA on the quality control of root canal obturation.Methods:The root canal proper-filling rate before and after the application of PDCA was compared.Results:The total root canal proper-filling rate reached the PDCA target.The root canal proper-filling rate of molar improved from 85.84%to90.45%.There was significant difference in the molar root canal proper-filling rate before and after the PDCA cycle.Conclusion:The application of PDCA facilitates the improvement of molar's root canal obturation and excerts a positive effect on the quality control of root canal obturation.
出处 《口腔医学研究》 CAS CSCD 北大核心 2015年第10期1029-1031,共3页 Journal of Oral Science Research
基金 广东省医学科研基金项目(编号:B2014029)
关键词 PDCA循环 根管充填 质量管理 PDCA Root canal obturation Quality control