摘要
制备了以N-(苯并〔1-3〕二噁茂-5-亚甲基)-1H-苯并咪唑-2-甲酰肼为载体的PVC膜电极.结果表明:该电极对铬(Ⅲ)离子在10-1~10-6mol/L的浓度范围内有良好的响应性能,响应斜率为22.9 m V/decade,检测下限为4.6×10-7mol/L.电极具有较好的抗干扰性、重现性和稳定性,能在p H值为1.13~6.15的范围内和体积分数小于20%的乙醇溶液中使用.可用于水样品中铬含量的直接测定和电位滴定Cr3+的指示电极.
A PVC Cr (IlI ) ion selective electrode based on N- ( benzo I d ] E 1,31 dioxol-5-ylmethylene )- 1H-bezon [d] imidazole-2-carbohydrazide (L) has been prepared. The results show that the electrode is high sensitive and selective to Cr3+. The response slope is 22.9 mV/decade in the range of 101-10-6 mol/L with the detection limit of 4.6 × 10-7 mol/L. The electrode is reproducible and stable, and could work in a certain concentration aqueous ethanol solution (volume percentage 〈 20% ) and certain range of pH (1.13 - 6.15 ). The proposed electrode has been used for the determination of Cr3+ ions in water samples and as an indicator electrode in potentiometric titration of Cr3+ ions with EDTA.
出处
《河南工业大学学报(自然科学版)》
CAS
北大核心
2015年第5期96-100,共5页
Journal of Henan University of Technology:Natural Science Edition
基金
郑州铁路职业技术学院骨干教师基金