依据DL/T 448-2000《电能计量装置技术管理规程》、JJG 596-2012《电子式电能表》等国家规程,供电企业每年需要定期更换大量的电能表。通过研制一种稳定可靠的电能表快速接线端子座,改变传统的电能表接线方式,实现单相电能表现场快速安装接线,并且在更换电能表时不需要停电,解决由于电能表接线错误、导线压接不牢固等原因造成的计量故障,大大提高电能表现场安装质量及工作效率,确保电能计量装置准确、安全可靠运行。
According to DL / T 448-2000 Technical administrative code of electric energy metering,JJG 596-2012 Electrical energy meters with electronics and other national regulations,power supply companies need to replace a large number of regular meters per year. Through the research of a stable and reliable power meter fast connection terminal block to change the traditional way of power meter wiring,which to realize the rapid field installation wiring of singlephase energy meter,and it does not require power outage when replace the meters,and resolves metering faults due to meter wiring errors,and not firmly crimp the wires and other causes,which greatly improve the meter site installation quality and efficiency,and guarantee the safe and reliable operation energy metering devices.
出处
《电测与仪表》
北大核心
2015年第19期67-73,共7页
Electrical Measurement & Instrumentation
关键词
电能表接插件
快速接线
温升
测试与应用
watt-hour meter plug
fast connection
temperature rise
testing and application