期刊文献+

某五星级酒店土壤源热泵系统设计与施工 被引量:1

Optimization Design and Construction of Ground-Source Heat Pump System for a Fivestar Hotel in Jiangsu Province
下载PDF
导出
摘要 详细分析了酒店建筑的冷、热负荷特性,通过对各冷热源方案的技术性、经济性比较,并结合业主的意见,设计采用地源热泵系统作为本项目的冷热源。对室外地埋管及热泵机房的设计作了介绍,分析了地源热泵系统地埋管换热器的冷热平衡问题。 The cold and heat load characteristic of hotel buildings are analyzed. The ground-source heat pump system is selected as the cold and heat source, with the technical and economical comparison of different heat and cold source programs and owners’ opinions. The design of the outdoor buried tube and the heat pump equipment room is introduced, and the cold and heat balance of soil heat exchanger is analyzed.
作者 孙鹏 孙家顺
出处 《建筑节能》 CAS 2015年第10期16-18,共3页 BUILDING ENERGY EFFICIENCY
关键词 酒店 冷热源 地源热泵 地埋管换热器 施工 hotel cold and heat source ground-source heat pump soil heat exchanger construction
  • 相关文献

参考文献5

  • 1王文生,陈树庆.山东寿光逐步推广地源热泵技术[N].中国建设报,2010-10-19(7).
  • 2JGJ134-2010,夏热冬冷地区居住建筑节能设计标准[S].
  • 3GB50366-2009,地源热泵系统工程技术规范[s].
  • 4地源热泵的工作原理及技术经济性分析[J].供热制冷,2011(3):60-61. 被引量:1
  • 5GB50736.2012.民用建筑供暖通风与空气调节设计规范[S].中华人民共和国住房和城乡建设部,中华人民共和国国家质量监督检验检疫总局,2012.