摘要
详细分析了酒店建筑的冷、热负荷特性,通过对各冷热源方案的技术性、经济性比较,并结合业主的意见,设计采用地源热泵系统作为本项目的冷热源。对室外地埋管及热泵机房的设计作了介绍,分析了地源热泵系统地埋管换热器的冷热平衡问题。
The cold and heat load characteristic of hotel buildings are analyzed. The ground-source heat pump system is selected as the cold and heat source, with the technical and economical comparison of different heat and cold source programs and owners’ opinions. The design of the outdoor buried tube and the heat pump equipment room is introduced, and the cold and heat balance of soil heat exchanger is analyzed.
出处
《建筑节能》
CAS
2015年第10期16-18,共3页
BUILDING ENERGY EFFICIENCY
关键词
酒店
冷热源
地源热泵
地埋管换热器
施工
hotel
cold and heat source
ground-source heat pump
soil heat exchanger
construction