摘要 大口径长焦透镜是高功率激光系统中必不可少的器件之一,随着装置性能提升,对长焦透镜透射波前包括透射峰谷(PV)值、透射均方根梯度(GRMS)值等,提出了详细的定量技术指标需求。根据长焦透镜焦距特别长的特点,提出了利用准直透镜,大幅缩短长焦透镜检测光路距离干涉检测方法。利用Zemax软件分析了该检测方法的理论误差和调整误差。该检测方法将光路长度由13 m(或33 m),大幅缩短至约5 m,光路受环境温度梯度、气流、震动的影响大幅降低,干涉结果直接显示透射波前畸变。 Large aperture long focal length lens is one of the necessary optics in the high power laser device.Along with the device upgrading, it proposes detailed transmission wavefront including transmission peak valley(PV)、transmission root mean square gradient(GRMS) for long focal length lens. According to the long focal length characteristic, this paper put forward an interference detection method, which utilizes a collimatied lens and a compensative lens to shorten the optical path length of the long focal lens detection and compensate the theoretical sphere aberration. Zemax is utilized to analyze and optimize the theoretical error and the distance adjustment error of the detection method.This method significantly shorten the optical path length of the long focal lens detection from 13 m(or 33 m) to about 5 m. The results show the transmission wavefront aberration of the tested lens.
出处 《中国激光》 EI CAS CSCD 北大核心 2015年第10期292-296,共5页 Chinese Journal of Lasers
关键词 测量 大口径 长焦透镜 透射波前 补偿测试 measurement large aperture long focal length lens transmission wavefront compensation test
  • 相关文献

参考文献16

二级参考文献63

  • 1赵东峰,戴亚平,尹宪华,邵平,华能,李海涛.高功率激光装置靶场光学系统的误差分析[J].中国激光,2004,31(12):1425-1428. 被引量:19
  • 2卢振武,刘华,李凤有.利用曲面计算全息图进行非球面检测[J].光学精密工程,2004,12(6):555-559. 被引量:24
  • 3乔战峰,赵东峰,戴亚平,李朝东,蒋敏华,华能,顾震.“神光-Ⅱ”第九路终端光学系统稳定性分析[J].强激光与粒子束,2006,18(3):419-422. 被引量:7
  • 4徐世祥,管富义,林尊琪,范滇元.高功率激光系统空间滤波器透镜焦距的选择及其测量[J].中国激光,1996,23(12):1077-1080. 被引量:7
  • 5王桂英 赵九源 张明科 等.钕玻璃高功率激光系统中的空间滤波器的基本研究[J].物理学报,1985,34(2):171-181.
  • 6SU D T. Optics Test Technology[M]. Beijing,Beijing Institute of Technology Press,1996.
  • 7Bernardo L M,Soares O D D. Evaluation of the focal distance of a lens by talbot interferometry[J].Appl Opt. 1988,27(2) :296-301.
  • 8Eliezer Keren,Kathi M Kreske,Oded Kafri. Universal method for determining the focal length of optical systems by Morie deflectometry[J]. Applied Optics, 1998,27(8): 1383-1389.
  • 9Daniel R NeaI,James Copland, David A,et al. Measurement of lens focal length using multi-curvature analysis of Shack-Harlmann wavefront data[A]. SPIE[C]. 2004,5523: 243-255.
  • 10LIU Hua, LU Zhen-wu, LI Feng-you. Using diffractive optical element and Zygo interferometer to test large-aperture convex surface[J]. Optics& Laser Technology. 2005,37(8) : 642-646.