摘要 液体自动颗粒计数器是当前液压污染控制技术领域不可或缺的关键性设备。针对该仪器的技术发展现状,详细分析了不同工作方式和测量原理的优缺点、以及性能参数对测量结果的影响,指出了仪器选用中应关注的主要问题,对液体自动颗粒计数器的正确选择和使用具有指导意义。 The automatic particle counter plays a critical role for liquid contamination control. The advantages and disadvantages of different work ways and measurement principles are analyzed in detail based on the current tech- nology development status of this instrument, and impacts of performance parameters on the measuring result are in- troduced. Meanwhile, the main problems concerned in choosing the instrument are pointed out. So, the paper has a guiding significance for correct selection and use of the automatic particle counter.
作者 郝新友
出处 《液压与气动》 北大核心 2015年第10期102-106,共5页 Chinese Hydraulics & Pneumatics
关键词 液体自动颗粒计数器 污染控制 液压传动 automatic particle counter for the liquid, contamination control, hydraulic fluid power