摘要 本文建立了硝酸消解环境监测领域中成分复杂的污水水样,电感耦合-等离子体发射光谱仪(ICPAES)同时测定水中3种重金属硼、铍和锑的方法。结果表明,硼、铍和锑的检出限分别是0.044、0.004和0.040mg·L-1,加标回收率为96.3%~101%,相对标准偏差均≤2%。方法简单、快速,适合环境水样检测,结果满意。该方法快速、简便,检出限低。 In this paper, a new method for the determination of Boron(B), Beryllium(Be) and Antimony (Sb) was developed by Inductively Coupled Plasma Optic Emission Spectrometry(ICP-OES). The samples were digest- ed with nitric acid medium. The results showed that the detect limits of B, Be and Sb were 0.044, 0.004 and 0.040 mg. L-l, respectively. The recoveries of B, Be and Sb were 96.3%-101%, and the relative standard deviations (RS- Ds) were less than 2%. The proposed method has simple operation and rapid analytical speed, and it is suitable for the determination of B, Be and Sb in environmental samples with satisfactory results.
出处 《化学工程师》 CAS 2015年第10期24-25,共2页 Chemical Engineer
关键词 硝酸消解 电感耦合等离子体原子发射光谱法 nitric acid digestion inductively coupled plasma optic emission spectrometry ( ICP-OES ) boron beryllium antimony