摘要 机械通气是ICU治疗重症患者的一个基本工具,也是全身麻醉的一个重要组成部分,但机械通气也可能导致并发症发生。对已经患病的肺进行机械通气或对原本正常的肺机械通气时可能造成肺结构和功能的显著改变,为了区别这两种情况,引用两个词:呼吸机相关肺损伤(VALI)和呼吸机诱发肺损伤(VILI),VALI是指先前存在肺损伤的患者,由于与呼吸机相关的因素导致肺损伤加剧或恶化,
出处 《检验医学与临床》 CAS 2015年第20期3119-3121,共3页 Laboratory Medicine and Clinic
  • 相关文献

参考文献28

  • 1De Prost N,Ricard JD,Saumon G,et al.Ventilator-in- duced lung injury:historical perspectives and clinical im- plications[J].Ann Intensive Care,2011,1(1):28.
  • 2Ngiam N,Kavanagh BP.Ventilator-induced lung injury: the role of gene activation[J].Curr Opin Crit Care,2012,18(1):16-22.
  • 3Cabrera-Bemtez NE,Parotto M,Post M,et al.Mechanical stress induces lung fibrosis by epithelial-mesenchymal transition[J],Crit Care Med,2012,40(2):510-517.
  • 4Ranieri VM,Suter PM,Tortorella C,et al.Effect of me- chanical ventilation on inflammatory mediators in patients with acute respiratory distress syndrome* a randomized controlled trial[J].JAMA,1999,282(1):54-61.
  • 5Hennus MP,Bont LJ,Jansen NJ,et al.Tidal volume drives inflammation during mechanical ventilation for viral respirato- ry infection[J],Pediatr Crit Care Med,2014,15(1):e27-31.
  • 6Nahum A,Hoyt J,Schmitz L,et al.Effect of mechanical ventilation strategy on dissemination of intratracheally in- stilled Escherichia coli in dogs[J].Crit Care Med,1997,25(10):1733-1743.
  • 7Murphy DB,Cregg N,Tremblay L,et al.Adverse ventila- tory strategy causes pulmonary-to-systemic translocation of endotoxin[J].Am J Respir Crit Care Med,2000,162(1):27-33.
  • 8Slutsky AS,Tremblay LN.Multiple system organ failure.Is mechanical ventilation a contributing factor?[J].Am J Respir Crit Care Med,1998,157(6 Pt I):1721-1725.
  • 9Yang M,Ahn HJ,Kim K,et al.Does a protective ventila- tion strategy reduce the risk of pulmonary complications after lung cancer surgery? A randomized controlled trial[J].Chest,2011,139(3):530-537.
  • 10Montes FR,Pardo DF,Charris H,et al.Comparison of two protective lung ventilatory regimes on oxygenation during one-lung ventilation:a randomized controlled trial[J].J Cardiothorac Surg,2010,5(5):99.

同被引文献44

  • 1李晓东.呼吸机使用前的功能测试及应对[J].中国医学装备,2004,1(1):50-50. 被引量:4
  • 2方玲,仪垂杰,丛红,周扬民,林海波.呼吸机通气模式综述[J].医疗装备,2006,19(6):1-4. 被引量:14
  • 3GOTHARD J. Lung injury after thoracic surgery and one-lung ven tilation[J]. Curr 0pin Anaesthesiol,2006,19(]):5 10.
  • 4LI C,LI Y S,XU M,et al. Limb remote ischemic preconditioning for intestinal and pulmonary protection during elective open infrarenal abdominal aortic aneurysm repair: a randomized controlled trial[J]. Anesthesiology, 2013,118 (4) :842--852.
  • 5SANTA C R, ALVAREZ L V, HERF.DIA R, et al. Acute respiratory distress syndrome: mortality in a single center according to different deft nitions[J]. J Intensive Care Med,2015,pii.-0885066615608159.
  • 6ZAPATA CHAVIRA H A, CORDEROPEREZ P, CASILLASRAMIREZ A, et al. Is ischemic preconditioning a useful therapeutic strategy in liver transplantation results from the first pilot study in Mexico[J]. ArchMeclRes,2015,46(4);296- 302.
  • 7HAUSENLOY D J, YELLON D M. Remote ischaemic preconditioning: underlying mechanisms and clinical application [J ]. Cardiovasc Res, 2008,79(3) =377--386.
  • 8KOZIAN A, SCHILLING T, ROCKEN C, et al. Increased alveolar damage after mechanical ventilation in a porcine model of thoracic surgery[J].J Cardiothorae Vasc Anesth,2010,24(4):617- 623.
  • 9I.I C,XU M,WU Y,et al. Limb remote ischemic preconditioning at- tenuates lung injury after pulmonary resection under propofol remifentanil anesthesia:a randomized controlled study[J]. Anesthe siology,2014,121(2) = 249- 259.
  • 10SEO Y J,LEE K T,RHO J R,ct al. Phorbaketat A,lsolateU trom the Marine Sponge Phorbas sp., Exerts Its Anti Inflammatory Effects via NF-BInhibition and Heme Oxygenaseq Activation in Lipopolysaccharide Stimulated Macrophages[J]. Mar Drugs, 2015, 13(11) ..7005--7019.