摘要 目的分析CT模拟定位在肿瘤三维适形精准放疗定位的临床应用价值。方法选取2013年9月~2014年10月来我院就诊的肿瘤患者59例,采用诊断多层螺旋CT进行肿瘤模拟定位扫描,采集图像经三维适形精准放疗计划系统(TPS)工作站进行分析后,在TPS系统中设计放疗方案并实施,患者放疗完成后进行CT复查。结果 59例肿瘤患者CT模拟定位结果准确,CT复查结果显示放疗效果完全缓解31例,部分缓解19例,肿瘤无变化7例,2例患者肿瘤病情进展,放疗效果良好,且放疗期间无明显并发症产生。结论 CT模拟定位应用于肿瘤患者三维适形精准放疗,能够增加肿瘤定位准确性,促进放疗效果提高。 Objective To study the CT simulation in the clinical value of tumor dimensional conformal radiotherapy precise positioning.Methods From September 2013 to October 2014,59 cases of patients with cancer in our hospital used diagnostic multislice spiral CT scanning tumor simulator.After image acquisition by precise three-dimensional conformal radiotherapy planning system(TPS) workstation for analysis,designed and implemented radiotherapy plan in the TPS system,carried out CT scans in patients after completion of radiotherapy.Results A total of 59 cases of cancer patients' CT simulation results were accurate,CT reviewshowed that 31 cases of patients were completely remission,19 cases were partial remission,the tumor did not change in 7 cases and 2 cases of tumor patients were progression,the radiation effect was good.And no significant complications occurred during radiotherapy.Conclusion CT simulator in cancer patients with accurate three-dimensional conformal radiation therapy can increase tumor localization accuracy,improve the promotion of radiotherapy.
作者 祁峰
出处 《中国继续医学教育》 2015年第28期44-45,共2页 China Continuing Medical Education
关键词 肿瘤 三维适形放疗 CT模拟定位 Tumor Three-dimensional conformal radiotherapy CT simulator
  • 相关文献

参考文献7

二级参考文献26

  • 1姚原,吴国华,林清,夏士安,钱咏梅,舒忠梅.CT模拟定位对肺癌三维适形放疗的影响[J].中华放射肿瘤学杂志,2005,14(3):213-214. 被引量:11
  • 2杨克柽,孙卫国,林意群.动态成像技术及其在精确放疗中的应用[J].国外医学(放射医学核医学分册),2005,29(3):136-139. 被引量:5
  • 3侯友贤,石卫民,李工,李志强,贾峻嵩,陈海.三维立体适形放疗治疗恶性肿瘤的临床应用(附830例报告)[J].解放军医学杂志,2007,32(7):664-666. 被引量:9
  • 4赵金早,周大明,赵九军.常规模拟定位和CT模拟定位的比较[J].现代生物医学进展,2007,7(8):1218-1219. 被引量:9
  • 5Yaremko BP,Guerrero TM,McAleer MF,et al. Determination of respiratory motion for distal esophagus cancer using four-dimensional computed tomography[J]. Int J Radiat Oncol Biol Phys,2008,70:145-153.
  • 6Yamashita H,Kida S,Sakumi A,et al. Four-dimensional measurement of the displacement of internal fiducial markers during 320-multislice computed tomography scanning of thoracic esophageal cancer[J]. Int J Radiat Oncol Biol Phys,2011,79:588-595.
  • 7Zhao KL,Liao Z,Bucci MK,et al. Evaluation of respiratory induced target motion for esophageal tumors at the gastroesophageal junction[J]. Radiother Oncol,2007,84:283-289.
  • 8Fukada J,Hanada T,Kawaguchi O,et al. Detection of esophageal fiducial marker displacement during radiation therapy with a 2-dimensional on-board imager:analysis of internal margin for esophageal cancer[J]. Int J Radiat Oncol Biol Phys,2013,85:991-998.
  • 9Li J,Wang L,Wang X,et al. Preliminary study of the internal margin of the gross tumor volume in thoracic esophageal cancer[J]. Cancer Radiother,2012,16:595-600.
  • 10郑小康,陈龙华.三维通形放疗临床实践[M].北京:人民卫生出版社.2001.

共引文献29

同被引文献49

引证文献6

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部