摘要
2DW-72/0.1-7型氢气压缩机为对称平衡两列两级水冷活塞式压缩机。它的二段气缸盖中间夹层生产时有循环冷却水水充满,冷却水上出下进起到了冷却降温的作用。文章是对二段气缸盖冻裂渗水漏水问题提出的各种修复方案。
The 2DW-72/0.1-7 type hydrogen compressor is a symmetrical balance of two series two stage water cooled piston compressor. It is the two section of the middle layer of the cylinder cover the production of circulating cooling water, cooling water, the cooling water into the role of cooling. The paper is on the two stage repair scheme of cylinder head crack seepage Water Leakage problems.
出处
《广东化工》
CAS
2015年第19期145-145,155,共2页
Guangdong Chemical Industry
关键词
氢气压缩机二段缸板
原因分析
解决办法
效果
hydrogen compressor
the two stage
the cause analysis
the solution effect