期刊文献+

北京市丰台区地铁站台的空气卫生质量 被引量:6

Air quality of subway platform in Fengtai District of Beijing
原文传递
导出
摘要 目的了解地铁站台空气卫生状况,为地铁卫生管理提供依据。方法按照《公共场所卫生监测技术规范》要求,对北京丰台区内地铁站台空气中细菌总数、CO、CO2、风速、温度、PM10、甲醛和集中空调通风管道中细菌总数、真菌总数、积尘量进行监测。结果丰台区各站台空气中细菌总数、CO、CO2、风速、温度、PM10监测结果均符合要求;站台内不同监测点空气质量差异无统计学意义(P>0.05);换乘站站台空气中PM10浓度高于非换乘站台(P<0.05)。各地铁线集中空调通风管道内壁细菌总数、真菌总数和积尘量监测结果差异无统计学意义(P>0.05)。结论除温度外,丰台区地铁站台空气质量和集中空调通风管道卫生状况良好。 [Objective]To understand the air quality of subway platform,provide the scientific basis for the health management.[Methods]According to the Rules of health monitoring for public places,the total bacterial count,CO,CO2,wind speed,temperature,PM10,formaldehyde in air of subway platforms,as well as the total bacterial count,total fungi count and dust amount in central air conditioning ventilation ducts of subway platforms in Fengtai District of Beijing were monitored. [Results]The monitoring results of total bacterial count,CO,CO2,wind speed,temperature and PM10 in air of subway platforms met the standards, and there was no significant difference in air quality among different monitoring points(P〈0.05). The PM10 concentration of transfer station platforms was higher than that of non-transfer station platforms(P〈0.05). There were no significant differences in monitoring results of total bacterial count,total fungi count and dust amount in central air conditioning ventilation ducts among different subway lines(P〈0.05).[Conclusion]Except temperature,the air quality of subway platforms and sanitary condition of central air conditioning ventilation ducts of subway platforms are good in Fengtai District.
出处 《职业与健康》 CAS 2015年第20期2828-2830,共3页 Occupation and Health
关键词 地铁 空气卫生质量 监测 Subway Air quality Monitoring
  • 相关文献

参考文献10

二级参考文献24

  • 1张松乐.近地面大气微生物本底调查研究进展[J].中国微生态学杂志,1996,8(5):40-44. 被引量:8
  • 2Joint Research Center Institute for the Environment Commission of the European Communities. Indoor Air Pollution by Formaldehyde in European Countries[R].Report No.7 of Environment and Quality of Life, EUR13216EN, 1990.
  • 3中国预防医学科学院环境卫生监测所编.北京:公共场所卫生监督监测手册[S].,1991.108-114.
  • 4杨旭.建筑及装饰材料卫生学评价系列综述之一,致病建筑综合症[J].中国卫生工程学,1994,4(4):145-151.
  • 5GB9672-1996.公共交通等候室卫生标准.[S].,..
  • 6.公共场所卫生标准检验方法.[S].,2001-01-01..
  • 7.室内空气溶血性链球菌卫生标准.[S].,2001-01-01..
  • 8GBT17220-1998.公共场所卫生监测技术规范.[S].,..
  • 9广州市地下铁道首期工程可行性报告 .北京市城建设计院 . 1991.12.
  • 10GB/T 17220-1998.公共场所卫生监测技术规范[S],1998.

共引文献132

同被引文献41

引证文献6

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部