摘要
结合南京某超深基坑钢筋混凝土地下连续墙施工实例,在简要介绍地下连续墙施工工艺基础上,重点分析钢筋混凝土地下连续墙接头产生混凝土绕流的成因及对工程质量的危害,据此,提出相应的防止措施,以期为类似工程提供有益的参考。
Combined with a super-deep foundation construction example in Nanjing, the paper simply introduce some construction measures of diaphragm wall,and focuses on analyzing the cause of the concrete flow around and the harm for engineering quality,according to this,putting forward the corresponding prevention measures,in order to provide a valuable reference for similar projects.
出处
《江苏建筑》
2015年第5期68-69,91,共3页
Jiangsu Construction
关键词
深基坑
地下连续墙
混凝土绕流
施工措施
super-deep foundation
diaphragm wall
the concrete flow around
construction measures