文章分析了常州某制衣厂地下车库地下室外墙及地下室底板和顶板混凝土的后浇带及施工缝的渗漏原因,结合现场勘查结果,进而提出相应的治理裂缝渗漏的施工方法及技术。
The paper analyses the post pouring belt and the reasons caused the leakage of joints in underground garage in a Changzhou garment factory basement exterior wall,bottom plate of basement and roof concrete.Combining the results of field survey, it puts forward the corresponding method and technology.