摘要 为了提升含空气层冷辐射板的性能,本文建立一种新型含空气层冷辐射板的数学传热模型,由模型计算得到的辐射板供冷能力和表面平均温度与实验结果的误差分别为9.20%和-4.00%,证明该传热模型的可靠性较高。对辐射板冷冻水铜管与导热板的接触形式进行两种改造,利用已验证的传热模型对改进后的冷辐射板进行分析计算。计算结果表明:在最优参数条件下,空气层厚度减小为1 mm时两种辐射板的供冷能力分别提高了36.92 W/m2和33.19 W/m2;冷冻水平均温度每降低1℃、室内温度每升高1℃辐射板供冷能力分别平均提高7.46 W/m2和7.54 W/m2;辐射板表面最大温差几乎不变,抗结露能力良好。可见,改进后含空气薄层的冷辐射板供冷和抗结露性能良好,适合推广使用。 In order to improve the performance of chilled radiant panel (CRP) containing air layer, we firstly established a mathematical heat conduction model of CRP with air layer and evaluated its reliability. The deviation of model and experimental results about CRP cooling capacity and surface temperature was 9.20% and - 4.00% , which indicated that the model had high reliability. Then we change the contact form of CRP's chilled water brass and thermal plate by two ways and used the verified model to analyze the performance of the transformed CRPs. The results showed that two CRPs' cooling capacity increased 36.92 W/m2 and 33.19 W/m2 when the air layer thickness was reduced to 1 mm under the optimal parameters ; the cooling capacity averagely increased 7.46 W/m2 and 7, 54 W/m: as chilled water temperature decreased per 1 ℃ and indoor temperature increased per 1 ℃ ; the CRP's surface maximum temperature difference was constant. In conclusion, CRP containing thin layer has better performance on the cooling and anti-condensation, and it has the potential to be widely used.
出处 《制冷学报》 CAS CSCD 北大核心 2015年第5期94-100,112,共8页 Journal of Refrigeration
基金 国家质检总局科技计划项目(2013IK090)~~
关键词 含空气层冷辐射板 供冷能力 抗结露 传热模型 chilled radiant panel containing air layer cooling capacity anti-condensation heat conduction model
  • 相关文献

参考文献14

  • 1Usibelli A, Greenberg S, Meal M, et al. Commercial-sec- tor conservation technologies [ R ]. Berkeley: Lawrence Berkeley National Laboratory, 1985.
  • 2Mendell M J. Nonspecific symptoms in office workers:a re- view and summary of the epidemiologic literature [ J]. In- door Air, 1994, 4( 3 ) :227-236.
  • 3John K Manley. Radiant heating, radiant cooling [ M ]. New York: School of Architecture, Pratt Institute, 1954.
  • 4Giesecke F E. Hot-water heating and radiant heating and radiant cooling [ M ]. Austin: Technical Book Company, 1946.
  • 5ASHRAE. ASHRAE Handbook: HVAC Systems and E- quipment, Panel heating and cooling [ M]. Atlanta: A- merican Society of Heating, Refrigerating & Air-Condition- ing Engineers, Inc. , 2012.
  • 6朱能,田喆,马九贤.冷天花冷却顶板热工性能分析[J].制冷学报,2000,21(2):19-28. 被引量:5
  • 7Nestor Fonseca, Cristian Cuevas, Vincent Lemort. Radiant ceiling systems coupled to its environment part 1 : Experi- mental analysis[ J]. Applied Thermal Engineering,2010,30 (14/15) : 2187-2195.
  • 8Abdelaziz Laouadi. Development of a radiant heating amt cooling model for building energy simulation software [ J ]. Building and Environment, 2004,39 (4) : 421-431.
  • 9Mumma S A. Ceiling radiant cooling panels employing heat-conducting rails:deriving tile governing heat transfer equations [ J ]. ASHRAE Transactions, 2006,112 ( 1 ) : 34- 41.
  • 10严继光.辐射换热天花板及含有该辐射换热天花板的空调.中国专利.ZL200820050512.9,2009-05-20.