期刊文献+

核电厂稳压器电加热器异常经验反馈 被引量:5

The Experience Feedback on Pressurizer Heater Abnormality in a New-built Nuclear Power Plant
下载PDF
导出
摘要 运行核电厂稳压器电加热器能否正常工作直接关系到核电厂的安全运行。通过对某新建核电厂调试期间稳压器电加热器故障事件进行剖析,结合电加热器制造安装工艺和工程试验验证,得出了该型号电加热器填充物的使用温度限值(140℃)。采用加速失效思想设计了预计电加热器寿命的试验,找到了电加热器热老化的相关规律。根据电加热器填充物使用温度限值和热老化规律,给出了电加热器使用保养建议和处理类似事件的经验反馈,对核电厂的安全运行有一定的指导意义。 It is critical that the electrical heater of the pressurizer works normally for PWR. Based on analyses for the heater failure events in a new nuclear power plant and combined with the heater manufacturing and installation process and related engineering test, some im-portant parameters, including filler temperature limits of no more than 140℃, and thermal ageing principle, are found out. It is helpful for providing advices and experience feedback for the usage and maintenance of heaters, and having some instructive meanings for the safe oper-ation of nuclear power plant.
出处 《中国核电》 2015年第3期239-244,共6页 China Nuclear Power
关键词 稳压器 电加热器 加速失效 热老化 经验反馈 pressurizer electrical heaters failure acceleration thermal ageing experience feedback
  • 相关文献

参考文献8

二级参考文献14

  • 1Jacobs P W M.[C]//11th Sym.(inter.)on Combust.,1967:457.
  • 2张仁.固体推进剂的燃烧与催化[M].长沙:国防科技大学出版社,1991:159-160.
  • 3化学辞典[M].上海:上海辞书出版社,1989:752.
  • 4中国核动力研究设计院.稳压器电加热元件技术规格书[S].
  • 5中国核动力研究设计院.稳压器电加热元件焊接用熔化环技术条件[S].
  • 6中国核动力研究设计院.稳压器电加热元件套管及其连接件技术条件[S].
  • 7RCC-MM3306Edition2000[S].
  • 8GB/T16702--1996压水堆核电厂核岛机械设备设计规范[S].
  • 9EJ/T1012-1996压水堆核电厂核岛机械设备制造规范[S].
  • 10广东核电培训中心.900MW压水堆核电站系统与设备[M]北京:原子能出版社,2004.

共引文献23

同被引文献8

引证文献5

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部