摘要 主控室是核电厂监视和控制中心。目前大屏幕显示技术在主控室已获得了广泛应用,其主要用于显示电厂总貌,并为操纵员提供电厂关键参数、重要设备状态和安全系统状态,使进入主控室的工作人员能够快速了解电厂当前运行状况。结合法规标准要求、国内外核电厂主控室大屏幕应用情况以及实际工程经验,对核电厂主控室大屏幕选型、系统配置、布置设计、抗震设计、画面设计等关键环节进行深入分析探讨,并总结出工程设计应用中的技术要点,为后续主控室大屏幕设计及应用提供参考和借鉴。 The main control room( MCR) is the surveillance and control center of nuclear power plant. At present,the technology of large display panel( LDP) is widely used in main control room to display the total appearance of the power plant,and provide operators the critical parameters,status of important equipment and safety system of the power plant,to make the personnel entering main control room learn the current operating conditions of the plant promptly. The key points including selection of large display panels,system configuration,layout design,aseismic design and graphical design,etc.,are analyzed and discussed combining with the requirements in regulations and standards and the application situations in nuclear power plant at home and abroad as well as the engineering experiences; and the main technical points in engineering design application are summarized,to provide reference for design and application of large display panels in subsequence main control rooms.
出处 《自动化仪表》 CAS 2015年第11期65-69,73,共6页 Process Automation Instrumentation
基金 国家科技重大专项基金资助项目(编号:K-B2012.058)
关键词 核电厂 CPR1000 主控室 抗震试验 非安全级设备 法规标准 Nuclear power plant CPR1000 Main control room Seismic test Non-safety equipment Codes and standards
  • 相关文献

参考文献6

  • 1国家能源局. NB/T 20058 -2 0 1 2 .核电厂控制室屏幕显示的应用[S] . 北京:原子能出版社,2012.
  • 2国家核安全局. HAFJ0055 -1 9 9 5 .核电厂控制室设计的人因工程原则[S] . 北京:国家核安全局,1995.
  • 3Nuclear Regulatory Commission. NUREG 0700 - 2002 Human -system interface design review guidelines [S]. US: NuclearRegulatory Commission,2002.
  • 4国家核安全局.HAF J0053-1995.核设备抗震鉴定试验指南[S].北京,1995.
  • 5Electric Power Research Institute. URD - volume HI - 1993Advanced light water reactor utility requirements documentCHAPTER10 man - machine interface system [S]. US: ElectricPower Re - search Institute, 1993.
  • 6吴官寅,昌海,张学刚,李广,王延阁.大屏幕显示系统在先进核电厂人机接口系统中的应用[J].原子能科学技术,2014,48(B11):966-970. 被引量:3

二级参考文献5

  • 1Electric Power Research Institute. URD-volume ]]I-1993 Advanced light water reactor utilityrequirements document CHAPTER10 man-ma- chine interface systems[S]. USA: Electric Pow- er Research Institute, 1993.
  • 2Nuclear Regulatory Commission. R. G. 1. 97- 2006 Criteria for accident monitoring instru- mentation for nuclear power plants[S]. USA: Nuclear Regulatory Commission, 2006.
  • 3中国国家标准化管理委员会.GB/T136242008核电厂安全参数显示系统的功能设计准则[S].北京:中国标准出版社,2008.
  • 4International Electrotechnical Commission. IEC 60960-1988 Functional design criteria for a safety parameter display system for nuclear pow- er stations[S]. Switzerland: International Elec- trotechnical Commission, 1988.
  • 5Institute of Electrical and Electronics Engineers. IEEE-603 1998 Criteria for safety system for nuclear power generating stations[S]. New York, USA : Institute of Electrical and Electronics Engineers, 1998.

共引文献3

同被引文献5

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部