摘要 介绍了一种即热空气源变频热泵热水系统,分析了水路模块与热泵模块的理论耦合,得到冷凝器出水流量和温度与热泵系统制热量的关系,以及承压水箱流量和温度与热泵系统制热量的关系。测试了机组在变工况下给用户提供42℃、6L/min热水的的运行特性,结果表明:运行时压缩机排气比循环加热式热泵热水器的排气温度和压力低并且稳定;运行的环境工况范围大,即在高温43℃和低温-7℃均可运行;制热COP随环境变化呈抛物线状变化,且在43℃、20℃和-7℃时,制热COP分别为12.6、4.5和3.8。 An instant-heated and frequency-conversion air source heat pump hot water unit was introduced.The essay includes the theoretical coupling of water way module with the heat pump module.It draws out the relationship between condenser water flow and the heat pump system,and the relationship between pressure tank flow and the heat pump system.The essay also includes the operation when the system produces 42℃,6L/min hot water in changing environment conditions.And the result indicates that the exhaust pressure and temperature are lower and more stable than traditional cyclic-heated heat pump water heater, the system can run in a large and variable environmental conditions such as 43℃ and -7℃,and the heat COP varies with the environment in shape of a parabola,and when the ambient temperature is 43℃,20℃and -7℃,heat COP are respectively 12.6、4.5 and 3.8.
出处 《流体机械》 CSCD 北大核心 2015年第10期61-66,共6页 Fluid Machinery
关键词 热泵热水器 即热 变频 热工特性 heat pump water heater instant -heated frequency -conversion thermal and dynamic characteristics
  • 相关文献

参考文献14

  • 1Ibrahim O,Fardoun F,Younes R,et al.Air source heat pump Water heater;Dynamic modeling optimal energy management and mini-tubes conden-sers[J].Energy,2014,64:1102-1116.
  • 2Bakirci K,Ozyurt O,Comakli K,et al.Energy analy- sis of a solar-ground source heat pump system with vertical closed-loop for heating applications[J].Ener- gy,2011,36;3224-3232.
  • 3Hepbasli A,Kalinci Y.A review of heat pump water heating systems[J].Renewable and Sustainable Ener- gy Reviews,2009,13;1211-1229.
  • 4Li D H W,Yang Liu,Lam J C.Zero energy buildings and sustainable development implications-a review[J].Energy,2013,54:1-10.
  • 5GB/T 23137-2008 家用和类似用途热泵热水器[S].
  • 6曹浩,袁明征.直热式空气源热泵热水机的技术分析[J].制冷,2013,32(3):64-68. 被引量:4
  • 7Techarungpaisan P,Theerakulpisut S,Priprem S.Mod- eling of a split type air conditioner with interg-reted water heater[J].Energy Conversion and Mana-ge- ment,2007,48(4):1222-1237.
  • 8Kim M,Kim M S,Chung J D.Transient thermal behav- ior of a water heater system driven by a heat pump[J].International Journal of Refrigeration,2004,27:415-421.
  • 9Dutta A KjYanagisawa TjFukuta M.An investigation of the performance of a scroll compressor under liquid refrigerant injection[J].International Journal of Re- frigeration,2001,24(6):577-587.
  • 10王松庆,张旭,贺士晶.地下水源热泵变流量运行方式区域适宜性[J].排灌机械工程学报,2014,32(7):572-577. 被引量:4