期刊文献+

基于CDEGS仿真计算的变电站接地系统设计 被引量:2

Grounding System Design Based on Simulation of CDEGS in Substations
下载PDF
导出
摘要 随着接地技术研究的不断深入,接地系统各项指标参数的计算也变得越来越精确。基于CDEGS软件系统中的各个模块对典型变电站接地网设计工作进行整合。首先运用其中RESAP模块的功能对土壤视在电阻率与测量间距之间的关系进行分析计算,建立拟建址地的土壤实际分层结构模型;其次运用FCDIST模块计算故障电流在接地系统以及接入其中的架空地线或者中性线间的分布情况;最后运用MALZ模块对变电站接地系统的安全性进行分析,对各项因素对地表跨步电压分布的影响进行模拟。最终确定该变电站接地网的设计方案,并结合建成的接地网实测接地电阻反演校验仿真计算的准确性。 With the development of grounding technique,parameters calculation of the substation grounding system become more and more precise.The design of grounding system is integrated based on modules of CDEGS software system.Firstly,the soil texture of proposed substation is modeled with the RESAP module.Secondly,distributions of fault current in the grounding system and the overhead earth wire which accessed to the grounding system or neutral point wire are calculated by using the FCDIST module.Thirdly,the security of grounding system is analyzed,and the variation of step voltage with the factors transformation is simulated using the MALZ module.Finally,the final design proposal is confirmed,and the accuracy of simulation is verified by the actual testing of ground resistance.
作者 张景翯
出处 《山东电力技术》 2015年第9期14-18,22,共6页 Shandong Electric Power
关键词 接地网 故障电流 地电位升高 跨步及接触电位差 安全性评估 grounding grid fault current ground potential rise touch and step voltages safety evaluation
  • 相关文献

参考文献12

  • 1GB/T50065-2011.交流电气装置的接地设计规范[S].
  • 2IEEE std80-2000 IEEE Guide for Safety in AC Substation Grounding [ S ].USA : IEEE, 2000.
  • 3水利电力部西北电力设计院.电力工程电气设计手册(电气一次部分)[M].北京:中国电力出版社,1989.
  • 4丁荣凤,吴万军.变电站接地装置的设计[J].电力学报,2000,15(3):225-227. 被引量:2
  • 5J.Ma and F.P.Dawalibi.Study of Influence of buried Metallic Structures on Soil Resistivity Measurements [C ].IEEE Transactions on Power Delivery, Vol.13, No.2, April 1998, pp.356-363.
  • 6J.Ma and F.P.Dawalibi.Influence of Inductive Coupling between Leads on Soil Resistivity Measurements in Muhilayer Soils [C ]. IEEE/PES Transactions on PWRD,Vol.13,No.4,pp.999-1 004, October 1998.
  • 7张波,吴锦鹏,肖红,范荣全,朱健,黄晓明.变电站内短路电流分流系数影响因素分析[J].高电压技术,2012,38(3):720-728. 被引量:37
  • 8G.Yu,J.Ma,and F.P.Dawalibi.Computation of return Current Through Neutral Wires in Grounding System Analysis [C]//Pro-ceedings of the third IASTED International Conference onPower and Energy System.Las Vegas,Nevada,Nov.8-10,1999,pp.455- 459.
  • 9邹军,袁建生,周宇坤,马信山.统一广义双侧消去法与架空线路-地下电缆混合输电系统故障电流分布的计算[J].中国电机工程学报,2002,22(10):112-115. 被引量:30
  • 10国家电网公司运维检修部.十八项电网重大反事故措施及编制说明[M].北京:中国电力出版社,2012.