EAST托卡马克装置的核辐射监测系统 被引量:9

Radiation monitoring system for EAST tokamak
下载PDF
导出
摘要 EAST(Experimental Advanced Superconducting Tokamak)现阶段D-D运行产生2.45 Me V聚变中子及次级核反应γ射线,为了解EAST运行期间辐射场的分布及强度,确保运行期间人员及环境的核辐射安全。针对EAST运行期间装置大厅内部存在较强的中子、伽马瞬变辐射场的特征,结合环境低本底辐射监测的需要,采用宽动态范围、快时间响应的场所辐射监测探测器,与高灵敏度、稳定性好的环境辐射监测探测器相结合的方式,围绕EAST装置布置13个辐射监测点,每点分别安装一台中子、伽马监测器。采用自行编写的Lab VIEW辐射监测软件进行数据采集,组建了一套EAST托卡马克装置的中子、伽马辐射剂量监测系统。该系统在2015年春季EAST实验中连续稳定运行了三个月,可靠性较高,获取了大量实验数据。监测系统满足EAST核辐射监测的要求,同时为后续开展聚变堆辐射安全与防护研究提供实验平台。 Background:During the experiment of Experimental Advanced Superconducting Tokamak (EAST), reaction of D-D may generate neutrons with energy of 2.45 MeV, and bremsstrahlung gamma rays and neutron activated gamma rays as well.Purpose:The aim is tostudy the radiation of neutrons and gamma rays in the EAST hall during the running of EAST tokamak and obtain the radiation doses under different modes and parameters by implementing a radiation monitoring system to diagnose some plasma parameters and ensure the radiation safety of the personnel and the environment around EAST.Methods:In consideration of the highly and transient radiation doses of neutrons and gamma rays contrast to the lowly environmental background during the plasma discharge in the EAST hall, the combination of high ranging and fast responding detectors are adopted in the EAST hall whilst high sensitivity and stability detectors are deployed in the environment. Thirteen monitoring points were selected around the EAST, each point contains a neutron detector and a gamma ray detector. Combination of Ethernet and twisted pair are adopted for the data transmission, and the radiation monitoring software based on LabVIEW was developed. Results:A radiation monitoring system of EAST tokamak was successfully built to monitor and save the real-time radiation dose rates of each detector, and to produce an alarm signal when abnormal dose rate happens. The radiation monitoring system had run stably for more than three months during the EAST experiment in the spring of 2015, and obtained many useful experimental data on fusion radiation safety and protection.Conclusion:The radiation monitoring system can well monitor the radiation around the EAST tokamak, and provide a platform for the future study of radiation safety and protection of the fusion reactor.
出处 《核技术》 CAS CSCD 北大核心 2015年第11期85-90,共6页 Nuclear Techniques
基金 国家自然科学基金(No.11261140328) 国家磁约束聚变科学计划(No.2015GB103000)资助
关键词 托卡马克 辐射监测 中子 Γ射线 EAST EAST Tokamak Radiation monitoring Neutron Gamma ray
  • 相关文献

参考文献8

  • 1Weng P D, HT-7U Team. The engineering design of the HT-7U tokamak[J]. Fusion Engineering and Design, 2001, 58/59: 827-831. DOI: 10.1016/S0920-3796(01)00479-3.
  • 2Hytmduk Kim, Hee-Seock Lee, Sukmo Hong, et al. Radioactivity evaluation for the KSTAR tokamak[J]. Radiation Protection Dosimetry, 2005, 116(1-4): 24-27. DOI: 10.1093/rpd/nci242.
  • 3Huang Q Y, Chai Z X, Chen Y X, et al. Design and analysis of the radiation shield and safety system for HT-7U tokamak[J]. Fusion Engineering and Design, 2003, 69(1-4): 749-756. DOI: 10.1016/S0920-3796(03) 00134-0.
  • 4Isamu Akiyama, Takashi Umehara, Toru Tayarna, et al. Radiation protection in the large tokamak device (JT-60) facility[C]. IRPA 10, Hiroshima, 2000:P-6a-314.
  • 5Huang Q Y, Chen Y X. Analysis of the radiation shield of HT-7U tokamak[C]. Materials for Advanced Energy Systems and Fission & Fusion Engineering, 2002: 146-152. DOI: 10.1142/9789812705198 0016.
  • 6柴竹新,吴宜灿,刘伯学.核聚变装置EAST高可靠性辐射防护控制系统[J].核电子学与探测技术,2005,25(1):28-31. 被引量:9
  • 7李桃生.中子辐射防护监测仪表的发展状况[J].辐射防护通讯,2003,23(2):15-20. 被引量:13
  • 8Li J P, Tang Y L, Shao B B, et al. Intelligent environmental neutron and gamma monitoring system[J]. High Energy Physics and Unclear Physics, 1988, 12(1): 12-18.

二级参考文献59

  • 1[1]Andersson I O, Braun J. A neutron rem counter. IAEA.Neutron Dosimetry, Proc. Symp. Harwell, Vol. 2,Vienna, 1963:87.
  • 2[2]Bramblett R L, Ewing R k, Bonner T W. A new type of neutron spectrometer. Nucl. Instrum. and Methods,1960,9(1):1.
  • 3[3]Awschalow M. Use of the multispere neutron detector for dosimetry of mixed radiation field. IAEA. Neutron Monitoring, Proc. Symp. Vienna, 1967:289.
  • 4[4]Ing H, Clifford T, Mclean T. ROSPEC-A simple reliable high resolution neutron spectrometer. Radi. Prot. Dose. ,1997, 70(1-4) :273.
  • 5[5]Sannikov A V, Mares V, Schraube H. High energy response function of bonner spectrometers. Radi. Prot.Dose. , 1997,70(1-4):291.
  • 6[6]Boot S J, Gibson J A B. A counter for measuring neutron dose equivalent from thermal to 10 keV. UKAEA, Atomic Energy Research Establishment, Harwell, Report AERER-9357, 1978.
  • 7[7]Hankins D E. A modified A-B rem-meter with improved directional dependence and thermal neutron sensitivity.Health Phys. , 1978,34(2) :249.
  • 8[8]Cosak M, Lesiecki H, Strzelszyk H. Dependence of the response of eight neutron dose equialent survey meters with regard to the energy and direction of incident neutron.Neutron Dosimetry, Proc. Eurtom. 4th Symp.Neuherberg, Report EUP-7448, 1981.
  • 9[9]Leake J W. An improved spherical dose equivalent neutron detector. Nucl. Instrum. and Methods,1968,63:329.
  • 10[10]Portal G, Seguin H, Wagner S. Calibration of dosemeters used for radiation protection in the European community.IAEA. Advances in Radiation Protection Monitoring, Proc.Symp. Stockholm, 1979:639.

共引文献20

同被引文献56

引证文献9

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部