期刊文献+

心率对左心功能指数、主动脉强化CT值及延迟时间的影响 被引量:6

The effect of heart rate on left cardiac function index,enhanced CT value of aorta and delay time
下载PDF
导出
摘要 目的:探讨心率对左心功能指数、主动脉强化CT值和延迟时间的影响。方法:连续选择进行冠状动脉CTA的患者74例,在对比剂注射参数相同的情况下,按照心率分为低心率组(≤75a/分)和高心率组(〉75次/分)。所得数据在0%~90%R-R间期以10%为间隔进行重组,分析心输出量、每搏输出量和射血分数,测量两组主动脉强化CT值和延迟时间。并对两组间的差异进行统计学分析。结果:在对比剂注射参数相同的情况下,高心率组心输出量高于低心率组(t=3.908,P〈0.05),但高心率组主动脉强化CT值和延迟时间均低于低心率组(t=2.536,3.454,P均〈0.05)。结论:掌握不同心率下心功能指数、主动脉强化CT值及延迟时间的变化有助于冠状动脉CTA扫描中对比剂注射参数的设定,获得优良的图像质量。 Objective:The purpose of this study was to evaluate the effect of heart rate (HR) on left cardiac function index, enhanced CT value of aorta and delay time. Methods:Seventy-four consecutive patients underwent dual-source CT angiography using the same parameters for contrast administration. Patients were divided into slow HR groups (≤75bpm) and fast HR groups (〉75bpm). All of the original data were reconstructed at 0% -90% R-R interval with 10% interval and the cardiac output,stroke volume and ejection fraction were analyzed. The enhanced CT value of aorta and delay time were measured. Statistical analyses were performed between the two groups. Results: Using the same parameters for contrast administration,the cardiac output of the fast HR group was higher than that of slow HR group, with significant difference (t=3. 908,P〈0.05). Yet the enhanced CT value of aorta and delay time were lower in fast HR group compared with that of slow HR group (t= 2. 536,3. 454;P〈0.05). Conclusion: Well knowledge about the variation of cardiac function index, enhanced CT value of aorta and delay time with different HR is very useful for designing contrast medium injection parameters and obtaining excellent image quality.
出处 《放射学实践》 北大核心 2015年第11期1111-1113,共3页 Radiologic Practice
关键词 心率 心输出量 冠状动脉造影 体层摄影术 X线计算机 Heart rate Cardiac output Coronary angiography Tomography,X-ray computed
  • 相关文献

参考文献10

  • 1Cademartiri F, Maffei E, Palumbo AA, et al, Influence of intra cor- onary enhancement on diagnostic accuracy with 64-slice CT coro- nary angiography[J]. Eur Radiol, 2008,18(3) : 576 583.
  • 2Lu JG,Lv B,Chen XB,et al. What is the best contrast injection protocol for 64 row multi-detector cardiac computed tomography [J]. Eur Radio,2010,75(2) :159 165.
  • 3徐怡,唐立钧,朱晓梅,徐海,祝因苏.双源CT冠脉成像评估冠脉狭窄不准确的原因分析[J].中国医学计算机成像杂志,2013,19(2):127-131. 被引量:18
  • 4Leber AW, Becker A, Knez A, et al. Accuracy of 64-slice compu- ted tomography to classify and quantify plaque volumes in the proximal coronary system:a comparative study using intravascular ultrasound[J]. J Am Coil Cardiol,2006,47(3): 672-677.
  • 5蒋孟茜,王鹤,王霄英,邹明宇,衣闯,胡刚,王蕊,赵承琳,姜健,张保翠,罗健,高福生.80kVp条件下碘克沙醇(270mgI/mL)应用于冠状动脉CTA检查的可行性研究[J].放射学实践,2014,29(3):249-253. 被引量:16
  • 6Tomizawa N,Komatsu S, Akahane M, et al. Influence of hemody namic parameters on coronary artery attenuation with 320-detec- tor coronary CT angiography[J ]. Eur J Radiol, 2012,81 ( 2 ) : 230 233.
  • 7Awai K, Hiraishi K, Hori S. Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dy- naraic CT involving injection protocol with dose tailored to patient weight[J]. Radiology,2004,230(1) :142 150.
  • 8H usmann L, Alkadhi H, Boehm T, et al. Influence of cardiac he- modynamic parameters on coronary artery opaeification with 64 slice computed tomography [J]. Eur Radiol, 2006, 16 ( 5 ) : 1111- 1116.
  • 9Zhu X,Zhu Y,Xu H,et al. Dual source CT coronary angiography involving injection protocol with iodine tailored to patient body weight and body mass index: Estimation of optimal contrast mate- rial dose[J]. Acta Radio,2013,54(2) :149 155.
  • 10康德强,赵晶,华海琴,彭楠,王玲璞,李胜鳌.低管电压扫描条件下个体化对比剂用量方案在冠状动脉CTA中的应用[J].中国介入影像与治疗学,2014,11(9):616-620. 被引量:5

二级参考文献28

  • 1Mowatt G, Cook JA, Hillis GS, et al. 64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis. Heart ,2008, 94: 1386-1393.
  • 2Miller JM, Rochitte CE, Dewey M, et al. Diagnostic performance of coronary angiography by 64-row CT. N Engl J Med, 2008, 359: 2324-2336.
  • 3Dey D, Lee C J, Ohba M, et al. Image quality and artifacts in coronary CT angiography with dual-source CT: initial clinical experience. J Cardiovasc Comput Tomogr ,2008, 2:105-114.
  • 4Nakanishi T, Kayashima Y, Inoue R, et al. Pitfalls in 16-detector row CT of the coronary arteries. Radiographies ,2005, 25:425-438.
  • 5Zhang S, Levin DC, Halpern EJ, et al. Accuracy of MDCT in assessing the degree of stenosis caused by calcified coronary artery plaques. Am J Roentgeno1,2008, 191:1676-1683.
  • 6Brodoefel H, Burgstahler C, Tsiflikas I, et al. Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. Radiology ,2008, 247:346-355.
  • 7Renker M, Ramachandra A, Schoepf UJ, et al. Iterative image reconstruction techniques: Applications for cardiac CT. J Cardiovasc Comput Tomogr ,2011, 5:225-230.
  • 8Liu J, Gao J, Wu R, el al. Optimizing contrast medium injection protocol individually with body weight for high-pitch prospective ECG-triggering coronary CT angiography. Int J Cardiovasc Ima-ging, 2013,29(5):1115-1120.
  • 9Zhu X, Zhu Y, Xu H, et al. Dual-source CT coronary angiogra- phy involving injection protocol with iodine load tailored to patient hody weight and hody mass index: Estimation of optimal contrast material dose. Acta Radiol, 2013,54( 2):149-155.
  • 10Tatsugami F, Husmann L, Herzog BA, et al. Evaluation of a body mass index adapted protocol for low dose 64-MDCT coro nary angiography with prospective ECG triggering. AJR Am J Rocntgenol, 2009, 192(3):635-638.

共引文献36

同被引文献51

引证文献6

二级引证文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部