摘要
在ARIES采集站的测试、检修过程中,比较常见的故障是Equipment not detected(检测不到设备)的故障。本文根据Equipment not detected出现时的故障现象,有针对性地分析了放电接口板被烧毁、采集站电源异常、不能正常传输时对应的电源电路,准确地定位了故障的原因,并介绍了相应的故障排除方法。
There are lots of reasons causing a failure called " equipment not detected" in ARIES RAM troubleshooting.This paper analyzes the related circuit in the following failures:the burned out of the lightening board,the abnormal of the RAM power and the break off of the transmission,and gives out the repair methods.