摘要 目的探讨分娩监护镇痛仪SRL998A(以下简称分娩监护镇痛仪)在无痛分娩中的应用。方法选择2014年6月-2015年6月在我院住院分娩中的120例产妇的临床资料进行回顾性分析。其中60例产妇采用非药物分娩监护镇痛仪监护下分娩,60例产妇采用常规处理,比较两组临床疗效。结果研究组第1产程、第2产程及总产程均显著短于对照组,差异有高度统计学意义(P〈0.01)。研究组镇痛显效率及总有效率均显著高于对照组,差异有高度统计学意义(P〈0.01)。研究组转剖宫产率显著低于对照组,产后2 h出血量显著低于对照组,差异均有高度统计学意义(P〈0.01)。两组胎儿窘迫、新生儿窒息的发生率比较差异无统计学意义(P〉0.05)。结论非药物分娩监护镇痛仪监护下进行无痛分娩,镇痛效果好,非药物,无创伤,能够帮助产妇缩短产程,减少转剖宫产率,减少产后出血。 Objective To discuss clinical efficacy of painless childbirth in guardianship of Childbirth care analgesia meter.Methods Clinical data of 120 puerperas were respectively analyzed.60 cases of painless childbirth in guardianship of Childbirth care analgesia meter were study group,and 60 cases received conventional treatment.Clinical curative effect of two groups were compared.Results The first stage of labor,the second stage of labor and total labor of study group were shorter than control group(P〈0.01).The efficiency and total efficiency of study group were higher than control group(P〈0.01).Cesarean section rate of study group was lower than control group,and 2 h postpartum bleeding of study group was less than control group(P〈0.01).Fetal distress,neonatal asphyxia rates of two groups showed no significant difference(P〉0.05).Conclusion Painless childbirth in guardianship of childbirth care analgesia meter shows analgesic effect,shorten women labor,reduce the transfer rate of cesarean section,and reduce postpartum hemorrhage.
出处 《中国现代医生》 2015年第32期61-63,共3页 China Modern Doctor
关键词 非药物 分娩监护镇痛仪 监护 无痛分娩 Non drug Child birth care analgesia meter Guardianship Painless childbirth
  • 相关文献

参考文献15

二级参考文献110

共引文献415

同被引文献47

引证文献4

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部