期刊文献+

TMG非侵入测量技术及其在运动科学应用中的研究综述 被引量:6

Research Overview on TMG Noninvasive Measuring Technique And its Application in Sports Science
下载PDF
导出
摘要 TMG(Tensiomyography)技术通过一个数字位移传感器测量肌肉肌腹的横向(径向)移动产生的生物力学变化来记录肌肉状态的改变,通过收缩时间(Tc),持续时间(Ts),延迟时间(Td),放松时间(Tr),径向位移(Dm)5个参数进行分析所测试肌肉的状态,用以评测肌肉功能,时间及形态上的对称性。本文综合了大量国外研究,包括TMG技术的重复性研究,评价下肢运动损伤中的应用,评价不同训练方式下肌肉状态中的应用,肌纤维类型测定研究以及不同年龄段肌肉状态的变化做研究综述。 TMG, recording the changes of muscle condi-tions through the biomechanics parameters measured from the lateral moving of muscle belly by spring loaded dis-placement sensor,time of muscle contraction( Tc) ,time of muscle relaxation( Tr) ,time of muscle sustains( Ts) ,time of muscle reaction delay ( Td ) , the radial displacement of the muscle( Dm) is used to evaluate the muscle functions and symmetry of time and form. The thesis is a literature review based on plenty of foreign research including the study on the repeatability of TMG and its application on sport rehabilitation,evaluation of the application of muscle in different training modes and evaluating the muscle fiber types and the changes of muscles in different ages.
出处 《南京体育学院学报(自然科学版)》 2015年第5期54-58,63,共6页 Joournal of Nanjing Institute of Physical Education:Natural Science
基金 江苏省高校自然科学研究项目(编号:13KJB320002)
关键词 TMG 肌肉状态 非侵入测量技术 肌肉功能 TMG muscle state noninvasive measurement muscle functional
  • 相关文献

参考文献26

  • 1王健,金小刚.表面肌电信号分析及其应用研究[J].中国体育科技,2000,36(8):26-28. 被引量:132
  • 2Mathur S, Eng J J, MacIntyre D L. Reliability of surface EMG during sustained contractions of the quadriceps [ J ]. J Electromyogr Kinesiol, 2005,15 (1) :102-110.
  • 3Olhvier K, Portero P, Maisetti O, Hopgrel J Y. Re- peatability of surface EMG parameters at various i- sometric contraction levels and during fatigue using bipolar and Laplacian electrode configurations[ J]. J Electromyogr Kinesio1,2005,15 (5) :466 - 473.
  • 4田石榴,刘宇.肌动图及其在运动医学研究中的应用[J].中国运动医学杂志,2009,28(3):349-352. 被引量:10
  • 5Massimiliano Ditroilo, Angus M Hunter. The effec- tiveness of two novel techniques in establishing the mechanical and contractile responses of biceps femoris. Physiol[ M]. Institute of Physics and Engi- neering in Medicine ~ Physiological Measurement, 2011,32(8) :1315 - 1326.
  • 6Dahmane R, Djorddievic S, ~imunic B, Valencic V. Spatial fiber type distribution in normal human muscle histochemical and tensiomyographical eval- uation[ J]. J Siomech ,2005,38 (12) :51 - 59.
  • 7Dahmane R, Djordievic S, Smerdu V. Adaptive po- tential of human biceps femoris muscle demonstra- ted by histochemical, immunohistochemical and mechanomyographical methods [ M ]. Medical & Bi- ological Engineering & Computing. 2006:999 - 1006.
  • 8Julio Tous-Fajardo, Gerard M, Sergio R J. Inter-rat- er reliability of muscle contractile property meas- urements using non-invasive tensiomyography [ J ]. Journal of Electromyography and Kinesiology, 2010,20(4) :761 -766.
  • 9Bo~tjan~imunic. Between-day reliability of a meth- od for non-invasive estimation of muscle composi- tion [ J ]. Journal of Electromyography and Kinesi- ology,2012,22(4) :527 -530.
  • 10Krizaj D, Simunic B, Zagar T. Short-term repeat-ability of parameters extracted from radial displace- ment of muscle belly [ J ]. Journal of Electromyogra- phy and Kinesiology, 2008,18 (4) : 645 - 651.

二级参考文献40

  • 1刘宇,彭千华,田石榴.老年人肌力流失与肌肉疲劳的肌动图研究[J].体育科学,2007,27(5):57-64. 被引量:24
  • 2Barry DT,Hill T,Dukjin I.Muscle fatigue measured with evoked muscle vibrations.Muscle Nerve,1992,15(3):303-309.
  • 3Mealing D,Long G,Mccarthy PW.Vibromyographic recording from human muscles with known fibre composition differences.Br J Sports Med,1996,30(1):27-31.
  • 4Orizio C.Muscle sound:Bases for the introduction of a mechanomyographic signal in muscle studies.Critical Reviews in Biomedical Engineering,1993,21 (3):201-243.
  • 5Keidel M & Keidal WD.The computer vibromyograpy as a biometric process in studying muscle function.Biomedizinsiche Technik,1989,34(2):107-116.
  • 6Lammert O,Jorgensen F,Einer-Jensen N.Accelerometermyography(AMG) I.Method for measuring mechanical vibrations from isometrically contracted muscles.In:P.Komi (Ed.),Biomechanics VA.Baltimore:University Park Press,1976,152-156.
  • 7Perry-Rana SR,Housh TJ,Johnson Go,et al.MMG and EMG responses during fatiguing isokinetic muscle contrac-tions at different velocities.Muscle Nerve,2002,26(3):367-373.
  • 8Beck TW,Housh T J,Johnson GO,et al.Comparison of a piezoelectric contact sensor and an accelerometer for examining mechanomyographic amplitude and mean power frequency versus torque relationships during isokinetic and isometric muscle actions of the biceps brachii.J Electromyogr Kinesiol,2006,16(4):324-35.
  • 9Courteville A,Gharbi T,Cornu JY.MMG measurement:a high-sensitivity microphone-based sensor for clinical use.IEEE Trans Biomed Eng,1998,45(2):145-50.
  • 10Stokes MJ,Dalton PA.Acoustic Myographic activity increases linearly up to Maximal voluntary isometric force in the human quadriceps muscle.Neurol Sci,1991,101(2):163-167.

共引文献139

同被引文献44

引证文献6

二级引证文献17