期刊文献+

H-ADCP流量在线监测系统软件设计与实现 被引量:11

Design and realization of on-line H-ADCP discharge measurement software
下载PDF
导出
摘要 受水利工程的影响,天然河流水文测验条件发生了很大变化,采用传统的水文测验方法获取河流断面完整的水文要素变化过程,势必要加大测次、增加成本。由于H-ADCP无法利用RTU进行数据测报与远程控制,其推广应用受到限制。采用H-ADCP进行流量在线监测是解决水利工程影响下流量测验的重要途径之一。长江水利委员会水文局在深入研究H-ADCP所带软件的基础上,研发了通用的H-ADCP在线测流系统。系统开发实现了H-ADCP远程控制在线监测及数据传输,具有较好的应用前景。 Influenced by water conservancy projects, the hydrological measurement condition in natural rivers changed greatly. To obtain the complete hydrological factor variation process would increase the measurement times and result in the increment of workload and cost. Using on - line H - ADCP discharge measurement software is an effective way to measure the discharge in the river channels influenced by water conservancy projects. However, the popularization and application of H - ADCP is limited be- cause the RTU can not be used to conduct remote control and prediction. On the basis of the intensive research on H - ADCP software, Hydrology Bureau of Changjiang Water Resources Commission developed a general on - line H - ADCP discharge meas- urement system, which realized the on- line and remote H -ADCP discharge measurement discharge and has a good application prospect.
作者 陈卫 周波
出处 《人民长江》 北大核心 2015年第21期39-42,共4页 Yangtze River
关键词 H-ADCP 流量在线监测 指标流速法 数值积分法 水资源监控 - ADCP on - line discharge measurement index flow velocity method digital integration method water re-source monitoring
  • 相关文献

参考文献2

二级参考文献7

  • 1李远青.H-ADCP在珠江三角洲思贤滘测流中的应用[J].佛山科学技术学院学报(自然科学版),2005,23(3):18-20. 被引量:4
  • 2RD Instruments, Broadband acoustic doppler current profiler[P]. United States Patent,, RE35535,1997-06 17,
  • 3李云中,胡焰鹏,叶德旭.H-ADCP自动流量监测系统在长江三峡河段的应用[A].全国水文学术讨论会论文集[c].南京:河海大学出版社,2004:462-466.
  • 4Rantz S E. Measurement and comparison of streamflow: volume 1, measurement of stage and discharge[R]. United States Geological Survey, Water-Supply Paper, 1982:2 175.
  • 5Morlock S E, Nguyen H T, Ross J H. Feasibility of acoustic doppler velocity meters for the production of discharge records from U. S. geological survey streamflow - gauging stations[R]. U.S. Geological Survey, Water-Resources Investigations Report 2002:1-4 157.
  • 6Ruhl C A, Simpson M R. Computation of discharge using the index-velocity method in tidally affected areas[R]. U S. Geological Survey, Scientific Investigations Report 2005:5 004.
  • 7WANG Fa-jun, HUANG He-ning. Horizontal acoustic doppler current profiler (H-ADCP) for real-time open channel flow measurement: flow calculation model and field validation[A]. Proceedings of ⅩⅩⅪ IAHR Congress, Water Engineering for the Future: Choices and Challenges[C]. Seoul, Korea, 2005:319-328.

共引文献3

同被引文献82

引证文献11

二级引证文献23