期刊文献+

麻醉深度指数在全麻患者手术期间麻醉深度监测中的应用 被引量:11

下载PDF
导出
摘要 目的:通过观察全麻患者手术过程中麻醉深度指数(CSI)的改变,以评估其在麻醉深度监测中的效果。方法:选取ASAⅠ或Ⅱ级的患者40例,随机均分为A组和B组,每组各20例。A组患者通过CSI改变判断麻醉深度来调节麻醉药物和剂量,B组患者则根据临床经验判断麻醉深度来调节剂置和用药。常规监测两组患者的收缩压、舒张压、心电图、心率、SPO2、CSI;记录两组患者的苏醒时间,在麻醉诱导期进行OAA/S(警觉/镇静)评分,计算CSI对于OAA/S的等级相关系数。结果:麻醉期间,A组患者的苏醒时间比B组要短,并且拔管后恶心、呕吐、嗜睡等不良反应少于B组;B组患者的收缩压、舒张压、心率、CSI波动明显大于A组(P<0.05);CSI与OAA/S评分具有显著的等级相关性。结论:CSI有助于判断患者的麻醉深度,指导麻醉用药。
作者 张立冬
出处 《中国民康医学》 2015年第21期15-17,共3页 Medical Journal of Chinese People’s Health
  • 相关文献

参考文献6

二级参考文献17

  • 1张宏.脑功能监测技术与麻醉深度判断[J].解放军医学杂志,2005,30(1):26-28. 被引量:16
  • 2涂学云,佘守章,许立新,闫焱,邬子林,肖颖琨.CSI与BIS指数用于监测硬膜外阻滞期间丙泊酚靶控镇静效应的比较[J].广东医学,2005,26(6):742-744. 被引量:31
  • 3徐国亭.麻醉深度指数用于高龄患者全麻期间麻醉深度监测的临床评价[J].第四军医大学学报,2006,27(19):1819-1820. 被引量:23
  • 4Bruhn J, Bouillon TW, Radulescu L, et al. Correlation of approximate entropy, bispectral index, and spectral edge frequency 95 (SEF95) with clinical signs of "anesthetic depth"during eoadministration of propofol and remifentanil. Anesthesiology, 2003, 98: 621-627.
  • 5Schmidt GN, Bischoff P, Standl T, et al. Comparative evaluation of the Datex-Ohmeda S/5 Entropy Module and the Bispectral index monitor during propofol-remifentanil anesthesia. Anesthesiology, 2004, 10: 1283-1290.
  • 6Struys MMRF, Vereecke H, Moerman A, et al. Ability of the bispectral index, autoregressive modelling with exogenous input-derived auditory evoked potentials, and predicted propofol concentrations to measure patient responsiveness during anesthesia with propofol and remifentanil. Anesthesiology, 2003, 99: 802-812.
  • 7Jensen E W, Lindholm P, Henneberg S W. Autoregressive modeling with exogenous input of middle-latency auditory evoked anesthes potentials to measure rapid changes in depth of a[J]. Meth Inform Med, 1996, 35:256-260.
  • 8Segaw H, Mori K, Kasai K, et al. The role of the phrenic nercves in stress response in upper abdominal surgery[J]. Anesth Analg, 1996, 82(6): 1215-1224.
  • 9Struys MM,Jensen EW,Smith W,et al.Performance of the ARXderived auditory evoked potential index as an indicator of anesthetic depth:a comparison with bispectral index and hemodynamic measures during propofol administration[J].Anesthesiology,2002,96(4):803-816.
  • 10Bru hn J,Boui llon TW,Radulescu L,et al.Correlat ion of approxim at e ent ropy,bisp ect ral ind ex,and s pectral edge frequency 95(SEF95)with clinical signs of anesthetic depth during coadministration of propofol an dremifentanil[J].Anesthesiology,2003,98(4):621-627.