摘要
针对DC 600V供电客车空调机组主电源加装漏电保护断路器后频繁出现意外分断现象,通过对漏电保护断路器原理和电源品质的综合分析、添乘试验和地面试验,查明了故障原因,并据此提出了针对运用客车和新造客车的解决措施。
In view of the unexpected breaking frequently happened in the DC 600 Vmain power supply for air-conditioner sets on passenger cars after equipping the leakage protection circuit breaker,through the comprehensive analysis of the principles of the leakage protection circuit breaker and the power supply quality,through testing on board and testing on the ground,the causes to the troubles are found out,and solution measures for operating passenger cars and newly manufactured passenger cars are given.
出处
《铁道车辆》
2015年第11期39-41,共3页
Rolling Stock
关键词
漏电保护断路器
意外分断
漏电流
布线电容
绝缘电阻
leakage protection circuit breaker
unexpected breaking
current leakage
wiring capacitance
insulation resistance