期刊文献+

Crack Initiation Mechanism of Z3CN20.09M Duplex Stainless Steel during Corrosion Fatigue in Water and Air at 290 °C 被引量:3

Crack Initiation Mechanism of Z3CN20.09M Duplex Stainless Steel during Corrosion Fatigue in Water and Air at 290 °C
原文传递
导出
摘要 The crack initiation mechanism of a Z3CN20.09M duplex stainless steel (DSS) during corrosion fatigue (CF) in water and air at 290 ℃ was investigated by using a CF cracking machine and a scanning electron microscopy (SEM). The cracks were initiated successively at the persistent stip bands (PSBs), phase boundaries (PBs) and pitting corrosion points (PCPs) of the specimens when they were tested in water at 290 ℃, while in airat 290 ℃ the cracks were only initiated at the PSBs and PBs. And the cracks were found mainly to initiate at the PSBs and PBs when the specimens were tested in water and air at 290 ℃, respectively. The results also reveal that the cracks were likely to be initiated at the first 20% of fatigue life of the specimens tested in water at 290 ℃. However, the cracks were not found until 50% of fatigue life when tested in air at 290 ℃. Moreover, the crack numbers of the specimens tested in water at 290 ℃ were much more than those tested in air at 290 ℃. The crack initiation mechanism of a Z3CN20.09M duplex stainless steel (DSS) during corrosion fatigue (CF) in water and air at 290 ℃ was investigated by using a CF cracking machine and a scanning electron microscopy (SEM). The cracks were initiated successively at the persistent stip bands (PSBs), phase boundaries (PBs) and pitting corrosion points (PCPs) of the specimens when they were tested in water at 290 ℃, while in airat 290 ℃ the cracks were only initiated at the PSBs and PBs. And the cracks were found mainly to initiate at the PSBs and PBs when the specimens were tested in water and air at 290 ℃, respectively. The results also reveal that the cracks were likely to be initiated at the first 20% of fatigue life of the specimens tested in water at 290 ℃. However, the cracks were not found until 50% of fatigue life when tested in air at 290 ℃. Moreover, the crack numbers of the specimens tested in water at 290 ℃ were much more than those tested in air at 290 ℃.
出处 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2015年第11期1144-1150,共7页 材料科学技术(英文版)
基金 financial support from the"863"Program of China under Nos.2008AA031702 and 2012AA03A507
关键词 Duplex stainless steel Corrosion fatigue Crack initiation High temperature water Duplex stainless steel Corrosion fatigue Crack initiation High temperature water
  • 相关文献

参考文献34

  • 1L. Llanes, A. Mateo, P. Villechaise, J. M6ndez, M. Anglada, Int.J. Fatigue 21 (1999) S1 19-S125.
  • 2Y.Q. Wang, J. Han, H.C. Wu, B. Yang,X.T. Wang, Nucl. Eng. Des. 259 (2013) 1.
  • 3J,K. Sahu, U. Krupp, H.J. Christ, lnt.J. Fatigue 45 (2012) 8-14.
  • 4YQ Wang, B. Yang, J. Han, H.C. Wu, X.T. Wang Mater. Trans. 54 (2013) 839- 843.
  • 5O.H.LI. Khalifa, J. Mater. Sci. Technol. 26 (2010) 810-816.
  • 6A.M.K. Dehghani, J. Mater. Sci. Technol. 26 (2010) 851-857.
  • 7A. Mateo, A. Giron0s, J. Keichel, L. Llanes, N. Akdut, M. Anglada, Mater. Sci. Eng. A314 (2001) 176-185.
  • 8A. Giron0s, P. Villechaise, A. Mateo, M. Anglada, J. M0ndez, Mater. Sci. Eng. A 387-389 (2004) 516-521.
  • 9S. Xu, X.Q. Wu, E.H. Han, W. Ke, Y. Katada, Mater. Sci. Eng. A 490 (2008) 16-25.
  • 10F. Xue, Z. Wang, G. Shu, W, Yu, H. Shi, W. Ti, Nucl. Eng. Des. 239 (2009) 2217-2223.

同被引文献7

引证文献3

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部