摘要 为设计适合国人的防护口罩,利用定量适合性检验和人体头面部尺寸测量的方法,探索影响口罩适合因子(FF)的因素。对4种颗粒物防护口罩(3M8210,3M8210v,3M9332和3M9010)的FF进行检测;测量口罩佩戴者的形态面长、面宽、两耳屏间宽、两下颌角间宽、鼻高、鼻长、鼻宽和两耳屏点间颌下弧长等头面部尺寸数据;计算身体质量指数(BMI)。探讨头面部尺寸、BMI、性别及口罩型号对FF的影响。研究表明:显著影响口罩FF的因素是头面部尺寸和口罩型号,其余因素对FF无显著影响;设计防护口罩应考虑我国人群头面部尺寸特点。 To explore factors influencing particulate respirator fit factors,quantitative fit tests were carried out with four kinds of respirators( 3M8210,3M8210 v,3M9332 and 3M9010). 26 men and 54 women were selected as respirator wearers. Their head and face dimensions were measured,including morphological facial length,bizygomatic breadth,bitragion breadth,bigonial breadth,nose height,nose breadth,nose breadth and bitragion-submandibular arc. Height and weight of the wearers were measured to compute BMI. Effects of head and face dimensions,BMI,gender and type of respirator on fit factor were analyzed.The experimental results show that head and face dimensions and type of respirator have significant effects on the fit factor,that remaining factors have no significant effect on factor,and that head and face dimensions should be taken into account to design efficient respirators.
出处 《中国安全科学学报》 CSCD 北大核心 2015年第3期121-125,共5页 China Safety Science Journal
基金 北京市自然科学基金青年项目资助(7144233)
关键词 颗粒物防护口罩 定量适合性检验 适合因子(FF) 影响因素 头面部尺寸 particulate respirators quantitative fit test fit factor influent factor head and face dimension
  • 相关文献

参考文献17

  • 1Gomersall C D, Tai DYH, Loo S, et al. Expanding ICU facilities in an epidemic: Recommendations based on experience from the SARS epidemic in Hong Kong and Singapore[J]. Intensive Care Medicine, 2006, 32 : 1 004 - 1 013.
  • 2Spies Adri, Kerry S Wilson, Ferrie Robert. Respirator fit of a medium mask on a group of south Africans: A cross-sec- tional study[J]. Environmental health, 2011, 10(1):1 -7.
  • 3R Kent Oestenstad, Leshan J Elliott, T Mark Beasley. The effect of gender and respirator brand on the association of res- pirator fit with facial dimensions[J]. Journal of Occupational and Environmental Hygiene ,2007,4(12) :923 -930.
  • 4程文娟,余艳艳,余丹,平杰,陈卫红.自吸过滤式防尘口罩适合性与头面部尺寸关系分析[J].中华劳动卫生职业病杂志,2012,30(5):352-355. 被引量:17
  • 5Zhuang Z, Coffey C C, Ann R B. The effect of subject characteristics and respirator features on respirator rit[J]. Journal of Occupational and Environmental Hygiene, 2005,2(12) :641 -649.
  • 6Zhuang Z, Bradtmiller B, Shaffer R E. New respirator fit test panels representing the current U. S. civilian work force[J].Journal of Occupational and Environmental Hygiene, 2007, 4(9):647 -659.
  • 7程文娟,余丹,余艳艳,等.方形、杯状N95过滤型口罩适合性与头面部尺寸关系分析[c].第九届全国环境与职业医学研究生学术研讨会论文集,2010:45—48.
  • 8Oestenstad R K, Dillion H K, Perkins L L. Distribution of faceseal leak sites on a half-mask respirator and their associa- tion with facial dimensions[J].American Industrial Hygiene Association Journal, 1990 ,51 (5) :285 -290.
  • 91910. 134 Occupational safety and health standards-respiratory protection[S].
  • 10GB2626--2006,呼吸防护用品自吸过滤式防颗粒物呼吸器[s].

二级参考文献15

  • 1GB/T2428-1998.成年人头面部尺寸.
  • 2Chen W, Zhuang Z, Benson S, et al. New respirator fit test panels representing the current Chinese civilian workers. Ann Occup Hyg, 2009, 53: 297-305.
  • 3Occupational Safety and Health Administration (OSHA): Code of Federal Regulations Title 29, Part 1910.134. 1998.
  • 4GB/T5703999.用于技术设计的人体测量基础项目.
  • 5Zhuang Z, Coffey CC, Lawrence RB. The effect of ambient aerosol concentration and exercise on PortaCount? Quantitative Fit Factors. J Int Soc Respir Protect, 2004, 21:11-20.
  • 6Zhuang Z, Groce D, Ahlers HW, et al. Correlation between respirator fit and respirator fit test panel ceils by respirator size. J Occup Env- iron Hyg, 2008, 5: 617-628.
  • 7Myers WR, Zhuang Z, Nelson T. Field performance measurements of half-facepiece respirators-foundry operations. Am Ind Hyg Assoc J, 1996, 57: 166-174.
  • 8Zhuang Z, Guan J, Hsiao H, et al. Evaluating the representativeness of the LANL respirator fit test panels for the current U.S. civilian workers. J Int Soc Respir Protect, 2004, 21: 83-93.
  • 9Yang L, Shen HG, Wu G. Racial differences in respirator fit testing: a pilot study of whether American fit panels are representative of Chinese faces. Ann Occup Hyg, 2007, 51: 415-421.
  • 10Du L, Zhuang Z, Guan H, et al. Head-and-face anthropometric sur- vey of Chinese workers. Ann Occup Hyg. 2008, 52: 773-782.

共引文献18

同被引文献87

引证文献15

二级引证文献69

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部