摘要
针对某公司硫酸装置焙烧炉风帽板发生频繁烧穿的现象,简要介绍了该事故背景,分析了风帽板安装时存在的安全隐患,以及事故发生的原因,介绍了大修时针对该事故采取的整改措施,以及整改后取得的效果。
For frequent penetration of the roaster hood in the sulfuric acid plant of a company,the background of the incident is briefly introduced,the safety risks during the installation of the hood,and the cause of the incident are analyzed. The corrective measures taken against the incident during the major overhaul,and the effects after the correction are introduced.
出处
《硫磷设计与粉体工程》
2015年第5期34-35,共2页
Sulphur Phosphorus & Bulk Materials Handling Related Engineering