摘要 分析了我国当前配电网分支线保护配置方案及其对用户年平均停电损失的影响,为降低用户年平均停电损失,提出一种分支线保护选配方法。该方法将分支线路分为3类,综合考虑分支线路负荷容量、长度等因素,通过比较配置不同保护时的用户年平均停电损失,选取最优配置方案,为现场选配分支线保护提供技术支持。为方便现场使用,对选配方法进行合理的简化处理,并通过实例分析验证了该选配方法能够有效减少用户年平均停电损失。 Branch line protection configuration scheme of distribution protection is analyzed.A method of protection selection is proposed to reduce the customer interruption cost.Load capacity and length of the branch line are taken into account in this method, and branch lines are divided into three categories.Optimal protection scheme is selected by comparing the interruption cost when using different protection scheme.This method can provide technical support for field use.The method is legitimately simplified for the convenience of field use, and it is verified by example analysis in reducing the customer interruption cost_
出处 《山东电力技术》 2015年第10期1-4,8,共5页 Shandong Electric Power
基金 国家863高科技项目-智能电网新型量测 通信 保护技术研究与开发(2012AA050213)
关键词 配电网 分支线 保护 用户停电损失 distribution network branch line protection customer interruption cost
  • 相关文献

参考文献4

二级参考文献15

  • 1万善良,胡春琴,张玲.配电网继电保护若干技术问题的探讨[J].供用电,2005,22(3):12-15. 被引量:16
  • 2周莉梅,范明天.城市电网用户停电损失估算及评价方法研究[J].中国电力,2006,39(7):70-73. 被引量:68
  • 3DL/T584-953~110kV电网继电保护装置运行整定规程[S].
  • 4肖湘宁,陶顺,徐永海.电能质量手册[M].北京:中国电力出版社,2010:351-354.
  • 5国家电网公司.Q/GDW156-2006国家电网公司城市电力网规划设计导则[S].北京:中国电力出版社,2006.
  • 6李光琦.电力系统暂态分析[M].北京:中国电力出版社,1998.
  • 7Oakes M C, Green M P. Developing Trends in Distribution Transformer Protection [C]// 4th International Conference on Trends in Distribution Switchgear, [s.n.], 1994: 157-162.
  • 8中华人民共和国国家发展和改革委员会.DL/T58420073kV-110kV电网继电保护装置运行整定规程[S].北京:中国电力出版社,2007.
  • 9南方电网公司.Q/CSC10703-2009南方电网公司110kV及以下配电网装备技术导则[S].北京:中国电力出版社,2009.
  • 10王正风.电网调度运行新技术[M].北京:中国电力出版社,2012.