期刊文献+

模拟人体组织介电特性的介电材料研究 被引量:7

Study on the Dielectric Materials Mimicking the Dielectric Properties of Human Tissues
下载PDF
导出
摘要 模拟人体组织相对介电常数和电导率的介电材料可用于分析1.5 T磁共振电特性断层成像技术的算法准确性和成像分辨率。为了得到各种人体组织模拟介电材料的具体组成,利用油、明胶、去离子水和氯化钠为主要成分制作了一组介电材料样本,其中油体积百分比范围为0%~80%,氯化钠浓度范围为0~1.40 g/100 m L。通过开端同轴线法测量这组介电材料样本在频率为64 MHz和温度为25℃时的介电特性,得到这组样本的电导率和相对介电常数变化范围分别为0.04~1.43S/m和12.6~83.4。利用非线性最小二乘拟合得到描述介电材料组成和其介电特性函数关系的经验公式。根据经验公式可以迅速得到各种人体组织模拟介电材料的组成。 The dielectric materials mimicking the relative permittivity and conductivity of various human tissues can be used to analyze the algorithm accuracy and image resolution of the magnetic resonance electric property tomography (MR EPT) technique at 1.5 T. In order to obtain the specific compositions of various human tissue- mimicking dielectric materials, a set of dielectric material samples were produced using oil, gelatin, deionized wa- ter and sodium chloride as chief ingredients, the ranges of oil volume percentage and NaC1 concentration were 0% ~ 80% and 0 ~ 1.40 g/100 mL respectively. The dielectric properties of these dielectric material samples were meas- ured using open-ended coaxial line method at the frequency of 64 MHz, and the measurement was taken under the temperature of 25 ℃. The ranges of conductivity and relative permittivity of the samples were 0. 04 - 1.43 S/m and 12.6- 83.4 respectively. Nonlinear least square fitting method was used to establish the empirical formulae be- tween the composition of dielectric material and its dielectric properties. According to the empirical formulae, the specific compositions of the dielectric materials mimicking various human tissues could be efficiently obtained.
出处 《科学技术与工程》 北大核心 2015年第33期24-29,共6页 Science Technology and Engineering
基金 国家自然科学基金(61172034) 广州市科学研究专项(2014J4100160)资助
关键词 介电特性 介电材料 开端同轴线法 非线性最小二乘拟合 dielectric properties dielectric material open-ended coaxial line method nonlinear least square fitting
  • 相关文献

参考文献20

  • 1Haacke E, Petropoulos L, Nilges E, et al. Extraction of conductivity and permittivity using magnetic resonance imaging. Physics in Medicine and Biology, 1991; 36(6): 723.
  • 2Voigt T, Katscher U and Doessel O. Quantitative conductivity and permittivity imaging of the human brain using electric properties tomography. Magnetic Resonance in Medicine, 2011; 66(2): 456-466.
  • 3Surowiec A J, Stuchly S S, Barr J B, et al. Dielectric properties of breast carcinoma and the surrounding tissues. IEEE Transactions on Biomedical Engineering, 1988; 35(4): 257-263.
  • 4Lazebnik M, Popovic D, McCartney L, et al. A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries. Physics in Medicine and Biology, 2007; 52(20): 6093-6115.
  • 5Chou C K, Chen G W, Guy A W, et al. Formulas for preparing phantom muscle tissue at various radiofrequencies. Bioelectromagnetics, 1984; 5(4): 435-441.
  • 6Kato H and Ishida T. Development of an agar phantom adaptable for simulation of various tissues in the range 5-40 MHz. Physics in Medicine and Biology, 1987; 32(2): 221.
  • 7Marchal C, Nadi M, Tosser A, et al. Dielectric properties of gelatine phantoms used for simulations of biological tissues between 10 and 50 MHz. International Journal of Hyperthermia, 1989; 5(6): 725-732.
  • 8Surowiec A, Shrivastava P N, Astrahan M, et al. Utilization of a multilayer polyacrylamide phantom for evaluation of hyperthermia applicators. International Journal of Hyperthermia, 1992; 8(6): 795-807.
  • 9Ito K, Furuya K, Okano Y, et al. Development and characteristics of a biological tissue‐equivalent phantom for microwaves. Electronics and Communications in Japan (Part I: Communications), 2001; 84(4): 67-77.
  • 10Lazebnik M, Madsen E L, Frank G R, et al. Tissue-mimicking phantom materials for narrowband and ultrawideband microwave applications. Physics in Medicine and Biology, 2005; 50(18): 4245-4258.

同被引文献43

引证文献7

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...