摘要
目的:建立培化磷脂酰乙醇胺中三氯甲烷残留量测定方法。方法:采用毛细管气相色谱法,色谱柱为DB-624;电子捕获检测器,柱温采用程序升温:起始温度为100℃,以50℃/min升至240℃,保持5 min。结果:在该色谱条件下,在0.04~7.1μg·m L-1范围内线性关系良好,相关系数为0.9993,平均回收率为100.3%,RSD为0.98%(n=9);检测限为10 ng·m L-1。结论:该毛细管气相色谱法灵敏、准确、可靠,适用于本品中有机溶剂残留量测定。
Objective: A GC method was established for determination of residual chloroform in phosphatidylethanolamine pegol. Method: Using a DB-624 capillary column, with ECD as detector and program temperature. The initial temperature was kept at 100℃, then the temperature was raised to 240℃ at the rate of 50 ℃.min4 and kept for 5 minutes. Results: The calibration curves of chloroform showed good linearity in the range of 0.04-7.1 ktg.mLl ( r=0. 9993). The average recovery was 100.3 % with RSD 0.98 % (n=9). The detection limit was 10 ng·mL^-l. Conclusion: The method is accurate sensitive, simple and reliable, it is suitable for measurement of residual chloroform in the phosphatidylethanolamine pegol.
出处
《广东化工》
CAS
2015年第22期174-175,共2页
Guangdong Chemical Industry
关键词
培化磷脂酰乙醇胺
残留溶剂
气相色谱法
三氯甲烷
phosphatidylethanotamine pegol
residual solvent: gas chromatography: chloroform