几种降阻措施在复合接地网中的应用 被引量:2

Application of several measures to reduce resistance in compound grounding grids
下载PDF
导出
摘要 目前降低变电站接地电阻主要采用的降阻措施常用的方法有增大接地网的面积、引外接地、增设垂直接地极、换土等。本文结合贵州地区实际变电站工程,介绍了以深井离子接地极为主的复合接地网在变电站接地中的应用及相关的参数计算。并对接地网设计中的注意事项作出小结。 The primary measures to reduce substation grounding resistance were as follows: expanding grounding net area, leading to external, adding the vertical grounding electrodes, exchanging the soil etc. Combining actual substation project in Guizhou area, this paper introduced deep well ion grounding composite ground net and its application and related parameters calculation in substation grounding. Lastly, the matters needing attention in the design of grounding systems were summarized.
作者 唐榕 陈宏伟
出处 《贵州电力技术》 2015年第11期89-92,共4页 Guizhou Electric Power Technology
关键词 变电站 降阻措施 复合接地网 深井离子接地极 substation measures to reduce resistance compound grounding grids deep well ion grounding
  • 相关文献

参考文献4

  • 1DL/T621《交流电气装置的接地》[s].
  • 2饶瑛.高土壤电阻率地区的接地设计[J].贵州电力技术,2008(8):47-49. 被引量:1
  • 3杨小光.《变电站接地系统降阻方案及接地材料选择》[D].华北电力大学硕士论文.
  • 4徐崇浩.《高土壤电阻率地区接地技术探讨》[D].中国国际防雷论坛论文摘编.