期刊文献+

FloTrac/Vigileo监测的研究进展 被引量:7

Progress of FloTrac/Vigileo System
下载PDF
导出
摘要 Flo Trac/Vigileo系统是一项微创且易建立的新技术,其可提供多项血流动力学参数,多用于监测患者的血流动力学状态以及指导液体管理治疗。Flo Trac/Vigileo系统在临床的应用中也存在不足之处,其获得的数据会受到置管通路和系统版本的影响。此外,多种可变因素也会影响Flo Trac/Vigileo系统测量结果的可靠性和真实性。据此,虽然Flo Trac/Vigileo系统有其优点,但目前仍不能替代有创监测,未来还需要更深入的研究。 The FloTrac/Vigileo system is a new technology, which is minimally invasive and easily estab- lished for continuous monitoring of hemodynamic and capacity, and it can provide a number of hemodynamic parameters for monitoring hemodynamie ~tatus and guiding fluid management. However in the elinical application, it also has defect, since the obtained data is affected by catheter pathway and system version. In addition, multiple variables will affect the FloTrac/Vigileo measured results' reliability and authenticity. Therefore,though FloTrac/Vigileo system has advantages, it still can't replace invasive monitoring, and further research in the future is still needed.
作者 吴洁 王天龙
出处 《医学综述》 2015年第22期4124-4126,共3页 Medical Recapitulate
关键词 血流动力学监测 容量状态 每搏量变异度 液体管理 Hemodynamic monitoring Capacity status Stroke volume variation Fluid management
  • 相关文献

参考文献22

  • 1Lopes MR, Oliveira MA, Pereira VO, et al. Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery:a pilot randomized controlled trial[ J ]. Crit Care, 2007,11 (5) : R100.
  • 2Mayer J, Boldt J, Mangistu AM, et al. Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients: a randomized, controlled trial[J]. Crit Care,2010,14( 1 ) :R18.
  • 3Benes J, Chytra I, A]tmann P, et aL Intraoperative fluid optimiza- tion using stroke volume variation in high risk surgical patients: results of prospective randomized study [ J ]. Crit Care, 2010, 14 (3) :Rl18.
  • 4Langewouters GJ, Wesseling KH, Goedhard WJ. The pressure dependent dynamic elasticity of 35 thoracic and 16 abdominal human aortas in vitro described by a five component model [ J ]. J Biomech, 1985,18(8) :613-620.
  • 5Cannesson M, Musard H, Desebbe O, et al. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients[J]. Anesth Analg,2009,108 (2) :513-517.
  • 6Zimmermann M, Feibicke T, Keyl C, st al. Accuracy of stroke vol- ume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery[ J ]. Eur J Anaesthesio1,2010,27 ( 6 ) :555-561.
  • 7Su BC, Tsai YF, Cheng CW, et al. Stroke volume variation derived by arterial pulse contour analysis is a good indicator for preload estimation during liver transplantation [ J ]. Transplant Proc, 2012, 44(2) :429-432.
  • 8Derichard A, Robin E,Tavernier B,et al. Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery [ J ]. Br J Anaesth, 2009, 103 ( 5 ) : 678-684.
  • 9Hofer CK, Senn A, Weibel L, et al. Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTracTM and PiCCOplusTM system [ J]. Crit Care, 2008, 12 (3) :R82.
  • 10Li J ,Ji FH ,Yang JP. Evaluation of stroke volume variation obtained by the FloTrae/Vigileo system to guide preoperative fluid therapy in patients undergoing brain surgery [ J ]. J Int Med Res, 2012,40 (3) :1175-1181.

同被引文献66

引证文献7

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部