期刊文献+

基于开放式绕组异步电动机的容错控制的研究

Fault-Tolerant Control for the Open-End Winding Asynchronous Motor
下载PDF
导出
摘要 开放式绕组异步电动机采用三相H桥拓扑结构,其输出电压能力与三电平逆变器相当。具有提高电动机供电电压,采用非弱磁方法提高电机转速和改善电压输出波形等优点。由于系统采用三相独立供电,系统所用的开关管个数增加,系统故障率提高。在对常见的短路和断路故障进行故障辨识和重构后,系统由剩余两相继续工作。容错控制时电机磁链幅值是正常运行时的3^(1/2)/3,仍能维持继续运行。最后经过实验验证,证明容错控制的可行性。 The open-end winding asynchronous motor adopts three-phase H bridge topology. And the output vohage ability is equal tothe three-level inverter. It can improve the motor power supply voltage, the motor speed without using the flux weakening and the output voltage waveform. Because the system adopts three-phase independent power supply, the switch tube used in the system number increases. So the system failure rate increases. After fault recognition and reconstruction of the common short circuit and open circuit fault, the remaining two phases of the system continue to work. The motor flux is of the normal control, which can still maintain continue running. Finally the feasibility of fault-tolerant control is proved by experimental verification.
出处 《微特电机》 北大核心 2015年第11期49-52,共4页 Small & Special Electrical Machines
关键词 开放式绕组 三相H桥 容错控制 open-end winding three-phase H bridge fault-tolerant control
  • 相关文献

参考文献8

  • 1TAKAHASHI I,OHMORI Y. High-performance direct torque con- trolofaninductionmotor[ J 1. IEEE Transactions on Industry Applica- tion, 1989, 25(2) : 257-264.
  • 2SOMASEKHA V T, GOPAKUMAR K, PITI'ET A, et al. A novel PWM inverter switching strategy for a dual two-level-inverter fed open-end winding induction motor drive [ C ]//4th IEEE Interna- tional Conference on Power Electronics and Drive Systems, 2001, 1 : 196-202.
  • 3SOMASEKHA V T, BAIJU M R, GOPAKUMAR K. Dual two-level inverter scheme for an open- end winding induction motor drive with a single DC power supply and improved DC bus utilization [ C ]//IEEE Proceedings on Electric Power Applications, 2004, 151 (2) :230-238.
  • 4SOMASEKHA V T, SRINIVAS S. Pulse width-modulated switc- hing strategy for the dynamic balancing of zero-sequence current for a dual-inverter fed open-end winding induction motor drive [ C ]//IET, Electric Power Applications,2007,1 ( 4 ) :591 - 600.
  • 5BAUU M R, MOHAPATRA K K, KANCHAN R S, et ah A dual two-level inverter scheme with common mode voltage elimination for an induction motor drive [ J ]. IEEE Transactions on Power Elec- tronics ,2004,19 ( 3 ) :794-805.
  • 6张兰红,胡育文,黄文新.采用瞬时转矩控制策略的异步发电系统的容错研究[J].航空学报,2005,26(5):567-573. 被引量:8
  • 7CRAIG E, MECROW B C,ATKINSON D J. A fault detection pro- cedure for single phase bridge converters [ C ]//Power Electronics and Applications, 1993, (4) :466-471.
  • 8郝正洋.六相永磁容错电机及其控制系统的设计和研究[D].南京:南京航空航天大学,2010:85-86.

二级参考文献12

  • 1Elbuluk M E, Kankan M D. Potential starter/generator technologies for future aerospace applications[J]. IEEE AES System Magazine, 1997,21 (5) : 24 - 31.
  • 2Alan I, Lipo T A. Starter/generator employing resonantconverter-fed induction machine. Part I : analysis [J].IEEE Transactions on Aerospace and Electronic Systems,2000,36(4):1309- 1318.
  • 3Kastha D, Bose B K. Investigation of fault modes of voltage-fed inverter system for induetion motor drive [J].IEEE Transaetions on Industry Applications, 1994, 30(4): 1028- 1038.
  • 4Blaabjerg F, Pedersen J K, Jaeger U,et al. Single current sensor technique in the DC link of three-phase PWM-VS inverters: a review and a novel solution[J]. IEEE Transactions on Industry Applications, 1997, 33 (5): 1241-1253.
  • 5Mendes A M S, Marques C A J. Voltage source inverter fault diagnosis in variable speed AC drives, by the average current Park's vector approach[A]. IEEE International Electric Machines and Drives Conference[C]. 1999.704-706.
  • 6Peuget R, Courtine S, Rognon J P. Fault detection and isolation on a PWM inverter by knowledge-based model [J]. IEEE Transactions on Industry Applications, 1998,34(6) :1318- 1326.
  • 7Ribeiro R L A, Jacobina C B, Silva E R C D, et al. Fault detection of open-switch damage in voltage-fed PWM motor drive systems[J]. IEEE Transactions on Power Electronics, 2003,18(2) :587-593.
  • 8Liu T H, Fu J R, Lipo T A. A strategy for improving reliability of field-oriented controlled induction motor drives[J]. IEEE Transactions on Industry Applications, 1993,29(5) :910-917.
  • 9Fu J R, Lipo T A. A strategy to isolate the switching device fault of a current regulated motor drive[A]. Proc IEEE IAS Annual Meeting[C]. 1993. 1015-1020.
  • 10Bolognani S, Zordan M, Zigliotto M. Experimental fault-tolerant eontrol of a PMSM drive[J]. IEEE Transactions on Industrial Electronics,2000,47(5) : 1134-1141.

共引文献7