期刊文献+

宫内节育器的ICD-10编码探讨

A Discussion on the ICD-10 Coding of Intrauterine Device
原文传递
导出
摘要 目的探讨宫内节育器诊断编码,提高医疗保健机构保健编码质量。方法检索某院自2012年5月到2015年4月间的出院诊断为宫内节育器的病案,对病案进行回顾性分析,依据ICD-10国际疾病编码分类原则,进行再编码。结果总计检索出1347份病案,其中,宫内节育器错误编码合计270例,错误率达20.04%。主要错误原因有临床医师诊断名称书写不规范、编码员没有联系病历前后记录进行编码、编码员对疾病编码分类掌握不足,编码不完全等。通过分析,对宫内节育器诊断有了进一步的认识,并给予匹配对应的ICD编码。结论加强病案首页疾病诊断与手术操作名称的完整、规范填写,编码员培养良好的阅读病案习惯、熟练掌握国际疾病分类方法、强化查阅疾病编码书籍的能力,才能提高编码准确性。 Objective To evaluate the coding of intrauterine device (IUI)), so as to improve the quatlty of comng in the health care organizations. Methods Retrieving from May 2012 to April 2015 discharge diagnosis contains "IUD" medical records which were retrospectively analyzed by rule. Then conducted recoding based on the ICD-10 coding principles. Results Total 1347 copies of the medical records retrieved, in which 270 cases of error code, the error rate was 20. 04%. Possible causes of error were : the not standardized name of the "IUD" diagnosis, there is not contact before and after when coding; coders are not familiar with the category of the disease coding and so on. Through analysis, we have a better understanding on the diagnosis of IUD and then matching the right ICD coding. Conclusions Strengthen the fully and normatively filling the diagnosis and surgical operation name of medical records, while coders should trying to develop the good reading habits of the medical records and master the methods of international classification of diseases. By this way, the coders can accurately encode according to read the medical records in contexts.
作者 陈菠
出处 《中国病案》 2015年第11期36-37,M0002,共3页 Chinese Medical Record
关键词 宫内节育器 ICD-10 疾病编码 Intrauterine device ICD-10 Coding of disease
  • 相关文献

参考文献8

二级参考文献41

  • 1孙爱军,高劲松,何方方,邓成艳,郁琦,董瑞峰,林守清.子宫异常出血合并血液系统出血性疾病的临床处理[J].中国医刊,2004,39(12):25-27. 被引量:7
  • 2邓姗,郎景和,冷金花,刘珠凤,孙大为,朱兰.曼月乐对子宫内膜异位症患者在位内膜增殖与凋亡的影响[J].生殖与避孕,2006,26(10):589-592. 被引量:112
  • 3吕映频,祁秀娟,段玉英,赵文翠,魏丽娜.左炔诺孕酮宫内缓释系统治疗功能失调性子宫出血的临床观察[J].现代妇产科进展,2006,15(10):753-756. 被引量:21
  • 4冯力民,王恩杰.宫腔镜子宫中隔切除术[J].中国微创外科杂志,2007,7(4):295-298. 被引量:15
  • 5夏思兰 FelixWong 李白新.妇科内镜学[M].北京:人民卫生出版社,2001.5..
  • 6Otero F J B,Guerrero C F J,Vazquez E L A.A comparative randomized study of three different IUDs in nulliparous Mexican women[J].Contraception,2003,67(4):273-276.
  • 7Pakarinen P,Toivonen J,Luukkainen T.Randomized comparison of levonorgestrel-and copper-releasing intraut-erine systems immediately after abortion,with 5 years follow-up[J].Contraception,2003,68(1):31-34.
  • 8Cao X,Zhang W,Zhao X,et al.Three-year efficacy and acceptability of the GyneFix 200 intrauterine system[J].Contraception,2004,69(3):207-211.
  • 9Veldhuis H M,Vos A G,Lagro J A L.Complications of the intrauterine device in nulliparous and parous women[J].Eur J Gen Pract,2004,10(3):82-87.
  • 10Mohllajee A P,Curtis K M,Peterson H B.Does insertion and use of an intrauterine device increase the risk of pelvic inflammatory disease among women with sexually transmitted infection? A systematic review[J].Contraception,2006,73(2):145-153.

共引文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部