摘要
对可能引起中压空气压缩机振动的各种因素进行分析,准确地诊断中压空气压缩机故障,并进一步提出有效的技术改造措施,最大限度地减少中压空气压缩机故障的发生,提高了中压空气压缩机的使用寿命。
Possible causes for the abnormal vibration of the medium pressure air compressor in Zhanghewan Pumped Storage Hydropower Station are analyzed .Therefore, faults of the medium pressure air compressor can be diagnosed ac-curately .Some effective technical improvement measures are also proposed , which could reduce the fault occurrence and improve the service life of the medium pressure air compressor .
出处
《水电与新能源》
2015年第11期53-55,共3页
Hydropower and New Energy
关键词
中压空气压缩机
振动
危害
原因
处理
medium pressure air compressor
vibration
hazard
cause
treatment