Comparison of the simulated gamma-ray attenuation coefficients with the real measurements

Comparison of the simulated gamma-ray attenuation coefficients with the real measurements
下载PDF
导出
摘要 The gamma-ray linear and the mass attenuation coefficients of Pb, Al, Cu, and plexiglass materials were calculated from both experimental and theoretical(simulation) methods. For the experimental results, a spectrometer, which was consisted of a Na I(Tl) inorganic scintillation detector, was used. The theoretical attenuation values were calculated by means of the FLUKA Monte Carlo(MC) and XCOM programs. Obtained attenuation coefficients from the experiment and the theoretical methods were compared with each other and literature values. The gamma-ray linear and the mass attenuation coefficients of Pb, Al, Cu, and plexiglass materials were calculated from both experimental and theoretical(simulation) methods. For the experimental results, a spectrometer, which was consisted of a Na I(Tl) inorganic scintillation detector, was used. The theoretical attenuation values were calculated by means of the FLUKA Monte Carlo(MC) and XCOM programs. Obtained attenuation coefficients from the experiment and the theoretical methods were compared with each other and literature values.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第5期53-57,共5页 核技术(英文)
基金 Supported by TUBITAK,the Scientific and Technical Research Council of TURKEY(No.197T087) EBILTEM,Center of Science and Technology,Ege University(No.99 BIL 001) the Scientific Research Project of Ege University(No.2011 FEN 085) Uludag University(No.OUAP(F)-2012/26)
关键词 质量衰减系数 Γ射线 实际测量 模拟 理论计算方法 闪烁体探测器 蒙特卡罗方法 玻璃材料 Gamma attenuation coefficients Na I(Tl) scintillation detector FLUKA XCOM
  • 相关文献

参考文献19

  • 1Knoll G E Radiation detection and measurements. John & Sons Inc., New York, 2000.
  • 2De Lima J J R Nuclear medicine physics. Taylor & Francis, USA, 2011.
  • 3Ferrari A, Sala P R, Fasso A, et al. Fluka: A multi-particle transport code. CERN, INFN/TC_05/11, SLAC-R-773, 2005.
  • 4Battistoni G, Cerutti F, Fassb A, et al. The FLUKA code: de- scription and benchmarking. AIP Conf Proc, 2007, 86:31--49.DOI: 10.1063/1.2720455.
  • 5Berger M J and Hubbell J H. (XCOM) Photon cross section on a personal computer. NB SIR 87-3597, 1987.
  • 6Ermis E E and Celiktas C. A different way to de- termine the gamma-ray linear attenuation coefficients of materials. Int J Instrum Sci, 2012, 1: 41-44. DOI: 10.5923/j.instrument. 20120104.01.
  • 7Ermis E E and Celiktas C. Determination of beta attenuation coefficients by means of timing method. Ann Nucl Energy, 2012, 41: 115-118. DOI: 10.1016/j.anucene.2011.11.003.
  • 8Medhat M E and Wang Y. Geant4 code for simula- tion attenuation of gamma rays through scintillation de- tectors. Ann Nucl Energy, 2013, 62: 316-320. DOI: 10.1016/j. anucene. 2013.06.034.
  • 9Demir N, Tarim U A, Popovici M A, et al. Investigation of mass attenuation coefficients of water, concrete and bake- lite at different energies using the FLUKA Monte Carlo code. J Radioanal Nucl Chem, 2013, 298: 1303-1307. DOI: 10.1007/s 10967-013-2494-y.
  • 10Tarim U A, Gurler O, Ozmutlu E N, et al. Monte Carlo cal- culations for gamma-ray mass attnuaion coefficients of some soil samples. Ann Nucl Energy, 2013, 58: 198-201. DOI: 10.1016/j. anucene. 2013.03.021.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部