Compressed sensing and Otsu's method based binary CT image reconstruction technique in non-destructive detection

Compressed sensing and Otsu's method based binary CT image reconstruction technique in non-destructive detection
下载PDF
导出
摘要 This paper tries to address the problem of binary CT image reconstruction in non-destructive detection with an algorithm based on compressed sensing(CS) and Otsu's method, which could reconstruct binary CT image of test object from incomplete detection data. According to binary CT image characteristics, we employ Splitbregman method based on L1/2regularization to solve piecewise constant region reconstruction. To improve the reconstructed image quality from incomplete detection data, we utilize a priori knowledge and Otsu's method as the optimization constraint. In our study, we make numerical simulation to investigate our proposed method,and compare reconstructed results from different reconstruction methods. Finally, the experimental results demonstrate that the proposed method could effectively reduce noise and suppress artifacts, and reconstruct high-quality binary image from incomplete detection data. This paper tries to address the problem of binary CT image reconstruction in non-destructive detection with an algorithm based on compressed sensing(CS) and Otsu’s method, which could reconstruct binary CT image of test object from incomplete detection data. According to binary CT image characteristics, we employ Splitbregman method based on L1/2regularization to solve piecewise constant region reconstruction. To improve the reconstructed image quality from incomplete detection data, we utilize a priori knowledge and Otsu’s method as the optimization constraint. In our study, we make numerical simulation to investigate our proposed method,and compare reconstructed results from different reconstruction methods. Finally, the experimental results demonstrate that the proposed method could effectively reduce noise and suppress artifacts, and reconstruct high-quality binary image from incomplete detection data.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第5期63-68,共6页 核技术(英文)
基金 Supported by the National Natural Science Foundation of China(Nos.61401049 and 61201346) Postdoctoral Science Foundation of China(No.2014M560703) Chongqing Postdoctoral Science Foundation(No.Xm2014105) the Fundamental Research Funds for the Central Universities(Nos.CDJZR14125501 and 106112015CDJRC121103)
关键词 CT图像重建 无损检测 OTSU方法 重建技术 压缩 OTSU法 传感 检测数据 Non-destructive detection Computed tomography(CT) Binary image reconstruction Compressed sensing(CS)
  • 相关文献

参考文献35

  • 1Kak A C and Slaney M. Principles of Comput- erized Tomographic Imaging. IEEE Press, 1988. DOI: 10.1137/1.9780898719277.
  • 2Wang G, Yu H, Man B D. An outlook on X-ray CT research and development. Med Phys, 2008, 35: 1051-1064. DOI: 10.1118/1.2836950.
  • 3Spencer K A. Computer tomography-An overview. J Photogr Sci, 1989, 37: 84-89.
  • 4Reddy M V, Lukose S N, Subramanian M P, et al. Industrial computed tomography system for aerospace applications: de- velopment and characterization. Insight, 2011, 53:307-311. DOI: 10.1784/insi.2011.53.6.307.
  • 5Luthi T, Flisch A and Wyss E Industrial computed X-ray to- mography. NDT International, 1998, 40: 196-197.
  • 6Ketcham R A and Carlson W D. Acquisition, optimization and interpretation of X-ray computed tomographic imagery: appli- cations to the geosciences. Comput Geosci, 2001, 27:381400. DOI: 10.1016/S0098-3004(00)00116-3.
  • 7He P, Wei B, Wang S, et al. Piecewise-constant-model-based interior tomography applied to Dentin tubules. Comput Math Method M, 2013, 892451. DOI: 10.1155/2013/892451.
  • 8Yu H, Wang G. Phys. Compressed sensing based inte- rior tomography. Med Biol, 2009, 54: 2791-2805. DOI: 10.1088/0031-9155/54/9/014.
  • 9Yang J S, Yu H, Jiang M, et al. High-order total variation minimization for interior tomography. Inverse Probl, 2010, 26: 035013. DOI: 10.1088/0266-5611/26/3/035013.
  • 10Meng B, Wang J and Xing L. Sinogram pre-processing and binary CT image reconstruction for accurate determination of the shape and location of metal objects with limited number of preprocessed projections. Med Phys, 2010, 37: 5867-5875. DOI: 10.1118/1.3505294.