摘要 埋地钢质管道受地铁动态直流杂散电流干扰的缓解是管道界的一个难题。本工作尝试使用强制电流阴极保护的方式,用强化的阴极保护电流缓解地铁动态干扰对管道的腐蚀影响。馈电试验有助于选取合适的强制电流阳极地床位置以及强制电流阴极保护系统的输出,取得最优的排流效果。 Mitigation of DC transit stray current interference is one of the challenges faced by pipeline industry. In this study impressed current cathoclie protection (ICCP) was tried to mitigate the DC interference from DC transit system, using enhanced CP current as a counteract measure to prevent corrosion. Current requirement test is an optimal method to choose the anode site and output parameters for ICCP system to get an optimized mitigation result.
作者 韩非
出处 《腐蚀与防护》 CAS 北大核心 2015年第11期1101-1103,1108,共4页 Corrosion & Protection
关键词 动态直流杂散电流 馈电试验 缓解 阴极保护 DC stray current current requirement testl mitigationl impressed current eathoclic protection(ICCP)
  • 相关文献

参考文献4

  • 1陈飞,周吉祥,牟南翔.埋地管道直流杂散电流排除实践[J].腐蚀与防护,2013,34(2):171-173. 被引量:13
  • 2NACE International CP Interference training material [M]. AtlantaJanuary NACE International, 2008.
  • 3GB21448-2008埋地钢质管道阴极保护技术规范[S].2008.
  • 4AS2832. 1--2004 Cathodic protection of metals partl : pipes and cables[S].