摘要 针对海口国际金融中心地下水及基坑土质情况,对其地下工程防水进行方案技术分析。因海南常年高温、多台风、多雨水,潮湿性较强,经与传统卷材防水方案进行对比分析,决定使用新型防水材料——CPS反应黏结型防水卷材技术进行防水设计。详细介绍了此种防水卷材在地下室底板、侧墙、顶板的施工工艺流程及施工中的质量控制关键要点。实践表明,该技术应用效果良好,经济合理。 Based on analysis of the ground water and geological condition of HNA International Financial Center,this paper researches the scheme of technological analysis of waterproofing for the underground project. Due to the hot temperature all the year and moist environment of Hainan Province,the new waterproof material,such as CPS waterproofing membrane is decided to apply compared with the scheme of traditional waterproof membrane. The waterproof membrane was applied to basement foundation slab,side wall and roof,and the construction process and key points for quality control is set out in detail. The application result is good,which proves the economy and efficiency of the material.
出处 《施工技术》 CAS 北大核心 2015年第21期96-100,共5页 Construction Technology
关键词 高层建筑 地下工程 防水 CPS反应黏结型防水卷材 质量控制 tall buildings underground waterproof chemical bonding and physical crosslinking synergism quality control
  • 相关文献

参考文献7

  • 1深圳市勘察测绘院海南分院.海口国际金融中心场地岩土工程勘察报告(详细勘察)[R].2012.
  • 2朱冬青.中国防水技术与市场现状和展望[J].中国建材,2003(2):69-75. 被引量:6
  • 3卢桂才,伍盛江,朱力伍,等.与混凝土进行化学交联和物理卯样协同黏结的防水卷材[P].中国:CNl01694114B,2011-07-06.
  • 4鄢长,李玥.海控国际广场地下工程防水技术[J].施工技术(下半月),2011,40(11):32-34. 被引量:1
  • 5中国建筑标准设计研究院.10J301地下建筑防水构造[M].北京:中国建筑工业出版社,2010.
  • 6总参工程兵科研三所.GB50108-2008地下工程防水技术规范[S].北京:中国计划出版社,2008.
  • 7GB50208-2011地下防水工程质量验收规范[S].北京:中国建筑工业出版社,2011.