摘要 研究了利用高效液相色谱-串联质谱法(LC—MS/MS)检测水产品中残留的5-吗啉甲基-3-氨基-2-嗯唑烷基酮(AMOZ)、氨基脲(SEM)、1-氨基-2-内酸脲(AHD)和3-氨基-2-噁唑烷基酮(AOZ)等4种硝基呋喃类代谢物,优化了前处理方法及液相色谱条件。硝基呋喃类代谢物经衍生化后,调节样品pH至7.0~7.5,加入8mL乙酸乙酯,离心并转移上清液,氮气吹干后,用乙腈-0.1%的甲酸水(5/95,V/V)溶液定容,4℃高速离心后上机测定。采用梯度洗脱法,4种代谢物在C18柱中分离良好。该法有效地提高硝基呋喃类代谢物的检测效率,且检测结果准确,适用于批量水产品的检测。 The nitrofuran metabolites (AMOZ, SEM, AHD and AOZ) were determined by liquid chromatography tandem mass spectrometry (LC-MS/MS) in aquatic products. The sample pretreatment method and chromatographic conditions were optimized. The sample pH value was adjusted to 7. 0 - 7.5 after derivation. Then the analytes were extracted by 8 mL ethyl acetate. Following centrifugation, the supernatant was transferred and evaporated to dryness under a gentle stream of nitrogen at 40 ℃. The residues were redissolved in 1 mL mobile phase of acetonitrile and 0. 1% formic acid (5/95, V/V), and then centrifuged at 20 000 × g for 10 min at 4 ℃. Gradient elution for LC separation was performed by using acetonitrile and 0. 1% formic acid in water solution, and four nitrofuran metabolites were excellently separated with a C18 column. This accurate optimized method can promote efficiency greatly and is suitable for lot determination of nitrofuran metabolites in aquatic products.
出处 《南方水产科学》 CAS CSCD 北大核心 2015年第6期58-64,共7页 South China Fisheries Science
基金 国家科技基础性工作专项(2014FY230100) 国家农产品质量安全风险评估重大专项(GJFP2014009) 中央级公益性科研院所基本科研业务费专项资金(中国水产科学研究院南海水产研究所)资助项目(2014TS28)
关键词 硝基呋喃类代谢物 高效液相色谱-串联质谱法 水产品 优化 nitrofuran metabolites liquid chromatography tandem mass spectrometry aquatic products optimization
  • 相关文献

参考文献20

二级参考文献72

共引文献119

同被引文献268

引证文献28

二级引证文献121

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部